AMCC 9550SX-8LP manual Whether to Use the LED Status Connector

Page 7

Before You Begin

„While the 3ware 9550SX RAID controller can be installed in both 64-bit PCI and PCI-X slots, not all slots give equal performance.

The 3ware 9550SX controller performs best when installed in a PCI-X 133MHz 64-bit slot. However, it can also operate at 66MHz or 100MHz.

Whether to Use the LED Status Connector

3ware RAID controllers include two types of LED status connectors:

„Overall indicator, which lights when any drive is active.

„Individual LED indicators, for each drive. (Not supported on chassis that have a common ground.)

If you are building a system from scratch, you may want to consider using a chassis or drive carrier that is compatible with the 3ware RAID controller activity LEDs, such as the AMCC RDC-400- SATA drive carrier, available through AMCC. Please check the 3ware web site (www.3ware.com) for chassis and drive carrier compatibility list.

For more information, see “Connecting Drive Activity LED Indicators” on page 17.

Most chassis have a single drive activity cable that you can connect to the overall activity indicator on the 3ware 9550SX controller. For the location of the overall drive activity connector, see the figure for the appropriate controller in the installation sections starting on page 18, and refer to Table 1, “LED Indicator Pin Positions,” on page 20.

Note: If you are using a chassis that includes a Chassis Control Unit (CCU), follow the instructions that came

with the chassis to connect the I2C cable from the CCU to the I2C connector on the 9550SX.

www.3ware.com

3

Image 7
Contents 3ware Trademarks CopyrightDisclaimer Table of Contents Appendix Technical Support Before You Begin Contents of PackageOther Documentation Installation ConsiderationsWhether to Use the LED Status Connector Personal Safety Safety FactorsWhat You Need Tools and Equipment Protecting Equipment and Data 9550SX RAID Controller Cards 9550SX 8-Port with Standard Sata Connectors9550SX 12-Port with Standard Sata Connectors 9550SX 4-Port with Standard Sata Connectors9550SX 16-Port with Multilane Internal Sata Connectors 9550SX 12-Port with Multilane Internal Sata ConnectorsTo connect Sata cables to the controller Installing a Serial ATA RAID ControllerSata Cables Being Inserted Into Port To install the controller in the computerInserting Controller Into PCI Slot To connect the Sata cables to the drives Sata Cable Connecting to DriveMultilane Serial ATA Cable InfiniBand 4x, SFF-8470 9550SX-12MIMultilane Cable Serial ATA SFF-8087 9550SX-16MLPage To install the drives LED connector details Connecting Drive Activity LED IndicatorsPort 3ware 9550SX-12 Serial ATA RAID Controller Additional Details About the LED Status Connectors LED Indicator Pin Positions Configure your RAID Arrays Check Installation and Close the CaseFinishing Up Installing an Amcc 3ware 9550SX RAID Controller Installing the Battery Backup Unit Tools and equipment required Installation OverviewPoints of connection on the half-height controller Removing the head from the plastic post Installation InstructionsPress down gently until the BBU is seated If you have a 4-port or 8-port 9550SX If you have a 12-port or 16-port 9550SX Shows the BBU fully installed on 3ware controllers BBU installed on controllers Replacing the Battery Removing the battery module Removing the power cable from the BBU module Feedback on this manual Sales and ordering informationAppendix Technical Support