Me Inc NumaLink-3.0 manual Frequently Asked Questions

Page 22

NumaLink-3.0™ Users Guide and Service Manual

3.If the systems are powered on, have you rebooted the NumaLink-3.0 system, the source system, and the destination system? (See section 2.1.3.)

4.Have you properly transferred a file from the source system? (See sections 5.4 and 6.)

5.4 Frequently Asked Questions

What types of data can I send through my NumaLink-3.0 system?

Your NumaLink-3.0 computer only supports raw, unprocessed data. This includes the following study types:

Static

Dynamic

Multi-Phase Dynamic

SPECT (planar/MUGA)

Gated SPECT

Whole Bodies

Some “Screen Save” data is supported from the following manufacturers:

GE StarCam

ADAC Pegasys

Sopha XT

When should I reboot my NumaLink-3.0 computer?

If your normal procedure is to shut down your nuclear medicine equipment nightly, then do the same with the NumaLink-3.0 system. If you leave your nuclear medicine equipment running all the time, Numa recommends rebooting the system once a week, preferably on a Monday. You should also reboot the NumaLink-3.0 system if you are experiencing trouble transferring files.

Can I load other software onto my NumaLink-3.0 computer?

We strongly recommends that you do not load any software onto your NumaLink-3.0 system. Doing so could cause the system to malfunction. If your system is covered under warranty by Numa Inc., loading unauthorized software onto the NumaLink-3.0 computer is in violation of the warranty terms and will void the warranty.

What about screen savers?

Screen savers take up a large amount of memory and resources on your NumaLink-3.0 system, may result in slow transfer times and may also cause the system to malfunction. Instead, you may turn off the monitor without disrupting normal system function.

Page 21 of 33

Image 22
Contents NumaLink-3.0 Version AprilFor more information contact Numa Table of Contents Introduction Hardware Installation and Getting StartedCabling Shutdown and Reboot StartupSoftware Installation DirectoriesLicense License Error Message Removing NumaLink-3.0Product Overview NumaLinkTypical Translation DicomPage Configuration GeneralNumaLInk-3.0 Dicom Application Entity Information Translations Translations Tab Translations Settings Customization DicomDicom dialog Dicom Settings Status NumaLink-3.0 Dicom Conformance StatementPage Remote Diagnostics Logging and Error ReportingTechnical Support Troubleshooting PcAnywhere IconFrequently Asked Questions Page Page NumaLink-3.0 Output Configuration Pegasys Write OEM Setup InformationNumaLink-3.0 Input Configuration Pegasys Read Adac PegasysGE StarCam NumaLink-3.0 Input Configuration StarCam ReadNumaLink-3.0 Input Configuration Odyssey Read Marconi OdysseyNumaLink-3.0 Input Configuration Icon Read Siemens IconCommand Line Interface and Configuration File Command LineConfiguration File Translate Directive Instead Outremoteae Directive Control* Directives