7.2 When the Copier Is Not Operating Correctly | 7 |
|
7.2When the Copier Is Not Operating Correctly
Symptom | Possible Cause | Remedy |
Nothing appears on the touch | If only the indicator on the | Press any key to cancel Energy |
panel. | [Start] key is lit, the copier is in | Saver mode. |
| Energy Saver mode. | (See section 1.5 in the Basic |
|
| Operations volume.) |
|
|
|
| The contrast control knob for | While looking at the touch |
| the touch panel has been set | panel, adjust the contrast |
| either too light or too dark. | control knob. |
|
| (See section 1.6 in the Basic |
|
| Operations volume.) |
|
|
|
| The scanner power cord or the | Set the power switch for the |
| interface cable are | copier to “O”, and then re- |
| disconnected. | connect the scanner power |
|
| cord and the interface cable. |
|
|
|
The indicator on the [Start] key | An access code has not been | Enter your access code. |
does not light up in green. | entered. | (See section 2.6 of the Basic |
|
| Operations volume.) |
|
|
|
Even though the [Start] key is | The copy/print job is queued for | Touch [Job Log] to check the |
pressed, no copies are made | printing. | jobs that are queued. Wait until |
|
| printing begins. |
|
|
|
| The copier is still warming up | The copier takes about 5 |
| after just being turned on. | minutes to warm up after it is |
|
| turned on. |
|
| Wait until the copier has |
|
| finished warming up. |
|
|
|
| The copier is malfunctioning | Follow any messages that |
|
| appear on the touch panel. |
|
|
|
Keys on the control panel do not | If the indicator on the [Interrupt] | Press the Interrupt key to |
respond. | key is lit, the copier is in | cancel the mode. |
| Interrupt mode. | (See section 2.4 in the Basic |
|
| Operations volume.) |
The copier cannot be turned on. | The power supply cord may | Plug the power supply cord into |
| have been unplugged from the | an electrical outlet. |
| electrical outlet. |
|
|
|
|
| The room’s circuit breaker was | Close the room’s circuit |
| tripped. | breaker. |
Troubleshooting Chapter 7
CF2002/CF3102 |