Qualstar 501440 Rev. G operation manual Status message Status Condition

Page 58

Apply power to the TLS library. During initialization, the library will reposition the cartridge handler and tape magazine carrousel. The tape drives and magazines will be scanned to inventory the contents of the library. The third line of the LCD displays the status of these operations.

If the Fibre Channel Option (FCO) is enabled and busy, it will also display status in- formation on the third line of the LCD. If there is more than one message to be dis- played, they will cycle at one-second intervals. Table 6-9shows the possible messages that can appear while the FCO is initializing.

Qualstar•••••TLS-4000

FC: Please Wait

On single Fibre Channel Option installations, status messages are prefixed with “FC:”. On dual installations, status messages for the left module are prefixed with “FCL:” and status messages for right module are prefixed with “FCR:”. The right and left module’s statue messages will alternate.

Status message

Status Condition

 

 

Please Wait

Waiting for Fibre Channel Option to complete restart initialization.

Reading Config

Reading the Fibre Channel Option configuration data.

Checking Config

Checking the Fibre Channel Option configuration.

Setting Config

Setting the Fibre Channel Option configuration.

Controller Reset

Resetting the Fibre Channel Option.

Table 6-9 Possible Fibre Channel Status Messages

If a serial communications error to the Fibre Channel Option is detected, the following warning will be displayed.

Fibre Channel Communications error detected ENTER to continue

Note that on dual bay libraries with two Fibre Channel Options installed the left or right FCO will be specified in the message. Pressing the ENTER key will clear the message.

This warning message can be caused by an incorrectly installed serial cable. If the message reoccurs after checking the cables and clearing the message using the EN- TER key several times, it may require power cycling the library, to reset the FCO. If this problem occurs, please contact the Technical Support department at Qualstar so that corrective action can be taken.

The initialization procedure can take up to several minutes. If the host system is started while FCO status messages are still present, the host may miss seeing the Fi- bre Channel devices because the system is still busy. The host should be instructed to scan for Fibre Channel devices after the FCO has been configured and line three is clear in the TLS Library’s LCD display.

6-18

FCO Type C Installation

501440 Rev. G

Image 58
Contents Fibre Channel Option 501440 Rev. GImportant Manual/Firmware Revision Information Copyright 2004 by Qualstar Corporation All Rights ReservedQualstar Corporation Table of Contents Maintenance Menu Maintenance\Fibre Channel\ Log Left or Right Status Screen Qualstar Who Should Read This ManualIntroduction Subject DocumentImportant Safety Information GefahrUnpacking UnpackingProduct Description General DescriptionFC Interface Link Models Type B Fibre Channel Option Product Description Fibre Channel Option FCO Type a Installation Considerations Drive Cabling for TLS-5/6/8000 and 58/68/88xxx LibrariesTLS-62xx and 82xx Drive Cabling Diagram Installing a Fibre Channel Option InstallationService Panel Rear View of TLS FCO Type a Installation Executive Pcba Identification Model CH0 Cable CH1 Cable CH2 Cable 10 Channel Connections 11 End View of D Connector on Gbic Adapter Initializing the Fibre Channel OptionStatus message Status Condition QualstarTLS-4000 FC Please WaitConfiguring the Fibre Channel Loop ID Dual Bay Library with two FCO’sConfiguring the Fibre Channel Scsi Devices Interface Rescan FCO Type B Installation Fibre Channel Option FCO Type B Installation ConsiderationsFCO Type B Interconnect Cabling Component Description Connectors on Rear of FCO Connectors on Rear of TLS-412xxx Cabling for TLS-412xxx LibrariesConnector Locations on the Rear of the TLS-412xxx TLS-412xxx Cabling Diagram Cabling for TLS-58xxx, 68xxx and 88xxx LibrariesConnectors on Rear TLS-58xxx, 68xxxRight Side TLS-58xxx/68xxx/88xxx Cabling Diagram Securing the Cables to the TLS Example of Cables Secured to the Rear of the TLSQualstarTLS-412180 FC Please Wait CFibreChannel Device Id Mode Configuring the Fibre Channel Scsi Devices Interface FCO Type B Installation FCO Type C Installation Fibre Channel Option FCO Type C Installation ConsiderationsFCO Type C Interconnect Cabling Bottom View of the Type C Fibre Channel Bridge/Router FCO Components Located on Bottom of FCO Connectors on Rear of TLS-42xx Cabling for TLS-4000, TLS-46xxx and TLS-412xxx LibrariesConnectors on Rear of TLS-44xx Preferred TLS-46xxx Fibre Channel Option Cable Connections Preferred TLS-412xxx Fibre Channel Option Cable Connections Connectors on Rear Cabling for TLS-5/6/8000 and 58/68/88xxx LibrariesTLS-54xx, 64xx and TLS-84xx TLS-58xxx, 68xxx and TLS-88xxx Installing a Fibre Channel Option 10 Rear View of TLS 11 Fibre Channel Option in the Open Position Serial 13 Executive Pcba Identification 14 Detail of Connections Executive IV Pcba Shown 16 End View of Small Form Factor Pluggable Transceiver Status message Status Condition Configuring the Fibre Channel Loop ID FCO Type C Installation Configuring the Fibre Channel Scsi Devices Interface Rescan Configuration Menu Configuration MenuFrom Figure Explanation Location digitConfiguration Menu Configuration\AdvancedFibre Channel Configuration\Advanced\Changer\Mechanics MenuFibre Channel Left Alarm Configuration\Advanced\Fibre Channel Left or Right MenuFibre Channel Right 4 Ch0..Ch5 Scsi Speed Fibre Channel Type B and C 2 Ch0 / Ch1 FC Speed Fibre Channel Type B and C3 Ch0..Ch5 Scsi ID Fibre Channel Type B and C Router LUNDate Year Date DayDate Month Time HourId Mode Left or Right Configuration\Fibre Channel MenuLoop Id Left or Right Topology 0 / Topology 1 Left or Right Loop Id Configuration\Fibre Channel\Device Left or Right Menu RescanScsi Lun Scsi ChannelScsi ID ManufMaintenance Menu Maintenance MenuPrivate menu access Maintenance Menu Backplane Id Maintenance\Fibre Channel MenuMaintenance\Fibre Channel\Info Left or Right Status Screen Base LvlMemory MB Board RevCpld Rev Daughtr Bd IdAir Temp Maintenance\Fibre Channel\ Log Left or Right Status ScreenUpdate CPU Temp Type a and B FCOs onlyLog Status Screen Sample Event text description Event Code Program Label Preparation for Packing Repacking the Fibre Channel OptionRepacking Remove the Gbic or SFP Adapter from the Fibre Channel Option Channel Connections in Type a FCO Detail of Auxpwr and Serial Connections in a Type a FCO Detail of Connections in a Type C FCO Packing the Fibre Channel Option Screw Locations in an FCO Type a Shown