Qualstar 501440 Rev. G operation manual Maintenance Menu

Page 76

8.

Maintenance Menu

 

 

.........Maintenance

.Display Log

.Display Prevents

.Display Revision

.Display Stats.

.Display Voltage

.Fibre Channel

SN: dddddddddd

.Test Inventory

.Test Keyboard

.Test LC Display

M........Display Log

.Display

.Display Left

.Display Right

BDC:

OFF

Clean

OFF

Configuration:

OFF

DriveBay:

OFF

Executive:

OFF

FC Events:

OFF

FC Replies:

OFF

FC States:

OFF

I2c:

OFF

Inventory:

OFF

Ioport

OFF

RBT Actions:

OFF

RBT Client:

OFF

RBT Events:

OFF

RBT I/O Port:

OFF

RBT Machines:

OFF

RBT Operations:OFF

RBT States:

OFF

SCSI Commands:

ON

SCSI Interrupt:OFF

SCSI Phases:

OFF

SCSI States:

OFF

Sequential:

OFF

CLEAR

 

LOCK

 

UNLOCK

 

MDL.Display....Entry

MDLD.Left......Entry

MDLD.Right.....Entry

At:ddddddddd.ddddd

BDC:

OFF

Clean

OFF

Configuration:

OFF

DriveBay:

OFF

Executive:

OFF

FC Events:

OFF

FC Replies:

OFF

FC States:

OFF

I2c:

OFF

Inventory:

OFF

Ioport

OFF

RBT Actions:

OFF

RBT Client:

OFF

RBT Events:

OFF

RBT I/O Port:

OFF

RBT Machines:

OFF

RBT Operations:OFF

RBT States:

OFF

SCSI Commands:

ON

SCSI Interrupt:OFF

SCSI Phases:

OFF

M...Display Prevents

Initiator 0

Initiator 1

Initiator 2

Initiator 3

Initiator 4

Initiator 5

Initiator 6

Initiator 7

Initiator 8

Initiator 9

Initiator 10

Initiator 11

Initiator 12

Initiator 13

Initiator 14

Initiator 15

Initiator L0

Initiator L1

Initiator L2

Initiator L3

Initiator L4

Initiator L5

Initiator L6

Initiator L7

Initiator L8

Initiator L9

Initiator L10

Initiator L11

Initiator L12

Initiator L13

Initiator L14

Initiator L15

Initiator R0

Initiator R1

Initiator R2

Initiator R3

Initiator R4

Initiator R5

Initiator R6

Initiator R7

Initiator R8

Initiator R9

Initiator R10

Initiator R11

Initiator R12

Initiator R13

Initiator R14

Initiator R15

M...Display Revision

Date: mm/dd/yyyy Part Number:700105

Revision: d.dd

Checksum: xxxx

M.....Display Stats.

.Left

.Right

Aborts: dddddddddd DoorOpn:dddddddddd Exchang:dddddddddd Filter: dddddddddd Grips: dddddddddd

ICalls:dddddddddd I Moves:dddddddddd I Steps:dddddddddd Minutes:dddddddddd Moves :dddddddddd Picks: dddddddddd Places: dddddddddd PowerOn:dddddddddd Resets: dddddddddd S Cmnds:dddddddddd X Moves:dddddddddd X Steps:dddddddddd Y Moves:dddddddddd Y Steps:dddddddddd Z Moves:dddddddddd Z Steps:dddddddddd

MDS.............Left

MDS............Right

Grips: dddddddddd

Picks: dddddddddd

Places: dddddddddd

XMoves:dddddddddd

XSteps:dddddddddd

YMoves:dddddddddd

YSteps:dddddddddd

ZMoves:dddddddddd

ZSteps:dddddddddd

SCSI States:

OFF

Sequential:

OFF

LOCK

 

Continued in Figure 8-2

Figure 8-1 The TLS Maintenance Menu (Part 1)

501440 Rev. G

Maintenance Menu

8-1

Image 76
Contents Fibre Channel Option 501440 Rev. GImportant Manual/Firmware Revision Information Copyright 2004 by Qualstar Corporation All Rights ReservedQualstar Corporation Table of Contents Maintenance Menu Maintenance\Fibre Channel\ Log Left or Right Status Screen Who Should Read This Manual IntroductionQualstar Subject DocumentImportant Safety Information GefahrUnpacking UnpackingProduct Description General DescriptionFC Interface Link Models Type B Fibre Channel Option Product Description Fibre Channel Option FCO Type a Installation Considerations Drive Cabling for TLS-5/6/8000 and 58/68/88xxx LibrariesTLS-62xx and 82xx Drive Cabling Diagram Installing a Fibre Channel Option InstallationService Panel Rear View of TLS FCO Type a Installation Executive Pcba Identification Model CH0 Cable CH1 Cable CH2 Cable 10 Channel Connections 11 End View of D Connector on Gbic Adapter Initializing the Fibre Channel OptionStatus message Status Condition QualstarTLS-4000 FC Please WaitConfiguring the Fibre Channel Loop ID Dual Bay Library with two FCO’sConfiguring the Fibre Channel Scsi Devices Interface Rescan FCO Type B Installation Fibre Channel Option FCO Type B Installation ConsiderationsFCO Type B Interconnect Cabling Component Description Connectors on Rear of FCO Connectors on Rear of TLS-412xxx Cabling for TLS-412xxx LibrariesConnector Locations on the Rear of the TLS-412xxx TLS-412xxx Cabling Diagram Cabling for TLS-58xxx, 68xxx and 88xxx LibrariesConnectors on Rear TLS-58xxx, 68xxxRight Side TLS-58xxx/68xxx/88xxx Cabling Diagram Securing the Cables to the TLS Example of Cables Secured to the Rear of the TLSQualstarTLS-412180 FC Please Wait CFibreChannel Device Id Mode Configuring the Fibre Channel Scsi Devices Interface FCO Type B Installation FCO Type C Installation Fibre Channel Option FCO Type C Installation ConsiderationsFCO Type C Interconnect Cabling Bottom View of the Type C Fibre Channel Bridge/Router FCO Components Located on Bottom of FCO Connectors on Rear of TLS-42xx Cabling for TLS-4000, TLS-46xxx and TLS-412xxx LibrariesConnectors on Rear of TLS-44xx Preferred TLS-46xxx Fibre Channel Option Cable Connections Preferred TLS-412xxx Fibre Channel Option Cable Connections Connectors on Rear Cabling for TLS-5/6/8000 and 58/68/88xxx LibrariesTLS-54xx, 64xx and TLS-84xx TLS-58xxx, 68xxx and TLS-88xxx Installing a Fibre Channel Option 10 Rear View of TLS 11 Fibre Channel Option in the Open Position Serial 13 Executive Pcba Identification 14 Detail of Connections Executive IV Pcba Shown 16 End View of Small Form Factor Pluggable Transceiver Status message Status Condition Configuring the Fibre Channel Loop ID FCO Type C Installation Configuring the Fibre Channel Scsi Devices Interface Rescan Configuration Menu Configuration MenuFrom Figure Explanation Location digitConfiguration Menu Configuration\AdvancedFibre Channel Configuration\Advanced\Changer\Mechanics MenuFibre Channel Left Alarm Configuration\Advanced\Fibre Channel Left or Right MenuFibre Channel Right 2 Ch0 / Ch1 FC Speed Fibre Channel Type B and C 3 Ch0..Ch5 Scsi ID Fibre Channel Type B and C4 Ch0..Ch5 Scsi Speed Fibre Channel Type B and C Router LUNDate Day Date MonthDate Year Time HourId Mode Left or Right Configuration\Fibre Channel MenuLoop Id Left or Right Topology 0 / Topology 1 Left or Right Loop Id Configuration\Fibre Channel\Device Left or Right Menu RescanScsi Channel Scsi IDScsi Lun ManufMaintenance Menu Maintenance MenuPrivate menu access Maintenance Menu Maintenance\Fibre Channel Menu Maintenance\Fibre Channel\Info Left or Right Status ScreenBackplane Id Base LvlBoard Rev Cpld RevMemory MB Daughtr Bd IdMaintenance\Fibre Channel\ Log Left or Right Status Screen UpdateAir Temp CPU Temp Type a and B FCOs onlyLog Status Screen Sample Event text description Event Code Program Label Preparation for Packing Repacking the Fibre Channel OptionRepacking Remove the Gbic or SFP Adapter from the Fibre Channel Option Channel Connections in Type a FCO Detail of Auxpwr and Serial Connections in a Type a FCO Detail of Connections in a Type C FCO Packing the Fibre Channel Option Screw Locations in an FCO Type a Shown