12 | Pathfinder Radar Scanners |
If you are mounting the scanner on the mast of a sailboat, and will need to unstep the mast, you should install a suitable junction box inside the boat.
On a radome scanner, the junction box should provide an 11- or 13- way terminal strip, depending on the number of power cores in your cable, with a 10 A rating. Also, you should keep the length of the un- screened coaxial cores to less than 30 mm to maintain EMC conformance.
On an open array scanner, the junction box should provide a
Inter-unit cable
The
Note: Route the cable from the display up to the scanner, since this will require the smallest clearance hole.
CAUTION:
The display connector on the
The
Table 1-3: Inter Unit Cables required for each Scanner Type
Scanner Package |
|
|
|
2D (US) | 10 m light (2 power cores) |
|
|
2DE (European) | 15 m light (2 power cores) |
|
|
4D | 15 m heavy (4 power cores) |
|
|
5S, 7S (4 kW) and 9S, 11S (10 kW) | 15 m heavy or radar arch kit |
Note: All 10 kW systems require a | (5 m + 10 m extension) |
minimum of 24 V. | 25 m heavy (24/32 V systems only) |
| |
The minimum bends permitted are: | |
Minimum bend, light cable | 60 mm (~2.5 in) radius |
Minimum bend, heavy cable | 82 mm (~3.75 in) radius |