16 | Pathfinder Radar Scanners |
Open array scanner cables
Inter-unit cable
Heavy duty cables are available in 15 m and 25 m lengths which should be sufficient to complete the cable run required on most small vessels. For longer runs, 5 m and 10 m extension cables are available, both have 4 power cores to minimize voltage drops over the cable run and incorporate
The maximum
CAUTION:
10 kW scanner systems cannot be used directly with 12 V systems; they require a 12 V to 24 V converter rated to 180 W. Contact your authorized Raytheon dealer or distributor for details.
12 V Systems (4 kW scanners only)
For vessels with 12 V power systems, the recommended cable(s) for different run lengths are given in the following table, which assumes a minimum supply voltage of 10.7 V (the lowest voltage likely to be reached by a 12 V battery in normal marine use). Do not use cable
combinations that are not included in the table.
Table
| 4 kW Scanners |
Length Required (m) | |
|
|
5 | 5m heavy |
|
|
15 | 15 m heavy |
15 | 5 m heavy + 10 m extension |
|
|
Refer to the packing list in Section 1.2 for cable part numbers
24 V and 32 V Systems - 4 kW scanners
For vessels with 24 V and 32 V power systems, any combination of