Chapter 1: Overview |
|
|
|
|
| 15 | |
| Table | ||||||
| 18" Radome Scanner |
|
|
|
| ||
|
|
|
|
| |||
|
|
| Power Cable Core (each core) |
| |||
| mm2: | 1.5 | 2.0 | 2.5 | 4.0 | 6.0 | 10.0 |
| AWG: | 16 | 15 | 14 | 11 | 10 | 7 |
|
|
|
|
|
|
|
|
| 10 m Light | 5.0 | 7.0 | 9.0 | 14.0 | 20.0 | 35.0 |
|
|
|
|
|
|
|
|
| 10 m Light + 5 m ext | 1.0 | 2.0 | 3.0 | 4.5 | 7.0 | 12.0 |
|
|
|
|
| |||
| 10 m Light + 10 m ext | Do NOT extend the power cable |
|
| |||
|
|
|
|
|
|
|
|
| 15 m Light | 1.0 | 2.0 | 3.0 | 4.5 | 7.0 | 12.0 |
|
|
|
|
|
|
|
|
| 15 m Heavy | 7.0 | 10.0 | 13.0 | 20.0 | 30.0 | 50.0 |
|
|
|
|
|
|
|
|
| 15 m Heavy + 5 m ext | 5.0 | 7.0 | 10.0 | 15.0 | 25.0 | 40.0 |
|
|
|
|
|
|
|
|
| 25 m Heavy | 4.5 | 6.0 | 8.0 | 12.0 | 20.0 | 35.0 |
|
|
|
|
|
|
|
|
| 25 m Heavy + 5 m ext | 3.5 | 4.5 | 6.0 | 9.0 | 15.0 | 25.0 |
|
|
|
|
|
|
|
|
| 25 m Heavy + 10 m ext | 2.0 | 3.0 | 4.0 | 6.0 | 9.0 | 15.0 |
|
|
|
|
|
|
|
|
Note: If you have an 18" radome scanner, and the wire gauge re- quired for your extended power cable is unacceptably large, you should replace the supplied light (2 power core)
Table
|
| Power Cable Core (each core) |
| |||
mm2: | 1.5 | 2.0 | 2.5 | 4.0 | 6.0 | 10.0 |
AWG: | 16 | 15 | 14 | 11 | 10 | 7 |
|
|
|
|
|
|
|
15 m Heavy | 5.0 | 7.0 | 9.0 | 14.0 | 20.0 | 35.0 |
|
|
|
|
|
|
|
15 m Heavy + 5 m ext | 4.0 | 5.0 | 6.0 | 10.0 | 15.0 | 25.0 |
|
|
|
|
|
|
|
15 m Heavy + 10 m ext | 2.0 | 3.0 | 4.0 | 7.0 | 10.0 | 17.0 |
|
|
|
|
|
|
|
25 m Heavy | 2.0 | 3.0 | 4.0 | 7.0 | 10.0 | 17.0 |
|
|
|
|
|
|
|
25 m Heavy + 5 m ext | 1.0 | 1.5 | 2.0 | 3.0 | 4.0 | 8.0 |
|
|
|
| |||
25 m Heavy + 10 m ext | Do NOT extend the power cable |
|
| |||
|
|
|
|
|
|
|