RF-Link Technology NL6000 manual Appendix B Factory Default Parameters, Factory Default Values

Page 48

Press ESC twice to return to the Main Menu.

Select Exit to save the Receive Diagnostic Mode setting and enter operating mode.

Appendix B - Factory Default Parameters

The following chart lists the default values set for each parameter at the factory. Use the last column to record any custom values you need to set.

Category

Parameter

Default Value

Custom Value

Radio

Unit Type

Remote

 

 

MYID

1234

 

 

TOID

FFFF

 

 

Active Channel

1

 

 

Rx Frequency on Active Channel

464.5500 MHz

 

 

Tx Frequency on Active Channel

464.5500 MHz

 

Serial

Baud Rate

9600

 

Data Bits

8

 

 

 

 

Stop Bits

1

 

 

Transmit Character Timeout

100

 

 

Transmit Character Timeout

None

 

 

DCD Mode

Disabled

 

 

Pre-Data DCD Time

500 msec

 

 

Post-Data DCD Time

500 msec

 

 

Diagnostic Programming Mode

Disabled

 

Data

Maximum Packet Size

300

 

 

Packet Mode

Enhanced Telem

 

 

Data Rate

12000 bps

 

 

ACKs

Disabled

 

 

Contention

CSMA

 

Repeater

Trigger

MYID

 

ID

0000

 

Entry

 

Transmit Channel

1

 

 

 

 

Transmit Delay (ms)

0

 

Table 5: Factory Default Values

RF Neulink

48

NL6000 User Guide

Image 48
Contents NL6000 Wireless Modem Copyright Table of Contents RF Neulink NL6000 User Guide RF Neulink NL6000 User Guide Use the NL6000 in a Simple Configuration Product OverviewFeatures Configuration Templates Single and Multi- Point AddressingAcknowledgement Auto-TransmitSafety Warning Regulatory InformationFCC Part 406.0 to 406.1 MHz OperationSpecifications General SpecificationsUHF Radio Specifications Current Drain at 12Transmitter ReceiverVHF Radio Specifications Hardware Installation and Operation Power ConnectionsParts Description Serial PortDTE DCEAntenna Connection LEDsOperation LEDSoftware Configuration Technical SupportPrerequisites PreparationUnique Data Requirements for a Base Station Source and Destination AddressingBehavior of Repeater Units Addressing with WildcardsRepeat from a Base to a Remote Repeat to Multiple Remotes using Wildcard Transmission Mode Packet Data OptionsCRC FECRF Neulink NL6000 User Guide Over-the-Air Data Rates AcknowledgementsCarrier Sense Multiple Access DCD ModeSerial Connection to an I/O Device Basic Serial ParametersFactory Default Parameters Planning the RF ChannelPre- and Post-Data DCD Time Procedures Select Network ä Unit TypeGeneral Procedures Displaying the Configuration Summary Window Returning to the Previous MenuRadio Network Setup Setting the Unit Type Select Network ä Unit TypeSetting the Unit ID Myid Select Network ä Myid Setting the Target Unit ID ToidSerial Connection Setup Data Setup Setting the Packet Mode Select Network ä Packet ModeSetting the Data Rate Select Network ä Data Rate Setting the Request ACKs OptionSetting the Contention Option Select Network ä Contention Setting the Max Retries OptionRepeater Setup Trigger ID Value UseDownloading a Software Upgrade File ManagementSelect Save/Restore Parameters ä Save Parameters to Disk Saving Parameters to DiskRestoring Parameters from Disk Restoring Default Parameters Menu Quick Reference Main Menu Summary WindowSerial Menu DCD RS-232 SubMenu Network Menu Repeater SubMenu Radio Menu Diagnostics Menu Save/Restore Parameters Menu Troubleshooting Other ConsiderationsDuty Cycle Use a Fully-Wired RS-232 Cable Unit Does Not Enter Programming ModeUse a Slower Baud Rate Use a Faster Baud RateAppendix a Diagnosing and Correcting Performance Problems Setting the Frequency Trim includes setting PowerSetting the Power Value Select Diagnostics ä Transmit Continuous Random DataSetting the Deviation and Balance ∙ Select Frequency Trim from the Diagnostics menuSelect Diagnostics ä Transmit 100 Hz Square Wave ∙ Select Radio Ä Transmit Frequency for Active ChannelSetting the Receive Gain ∙ Select Deviation from the Diagnostics menu∙ Select Diagnostics ä Receive Diagnostic Mode ∙ Select Diagnostics ä Receive GainAppendix B Factory Default Parameters Category Parameter Default Value Custom ValueFactory Default Values Index RF Neulink NL6000 User Guide