one without any interruption in Fibre Channel service. However, if external power is completely lost, all Fibre Channel ports will go into a standby mode after a short user- defined timeout period because the system will power off.
Warning:
Do not remove both power supplies from the system at the same time. This will cause system failure since the internal batteries require that at least 1 power supply be present in the system at all times. If both supplies are physically removed from the chassis, possible data loss may occur.
“On” switch
Low Voltage
Battery
Figure 2-3 RamSan-210 Power Supply Modules
The following buttons and indicators are on the power supply:
∙The top button provides a means to activate the power supplies (turn them on) after a
∙Low Voltage indicator light. The top indicator light shows when the power supply is operating below the voltage necessary to power the entire system. Low voltage indications are a sign that the power supply needs to be monitored and possibly replaced.
∙Battery Operation indicator light. The bottom indicator light shows when the system is operating from battery power. The system should only operate from battery power when external AC power has failed.
Warning:
The power supply modules maintain high voltage levels during normal operation. To prevent the risk of electrical shock, remove the power cord and wait 15 seconds before removing a power supply module.