Rack Mount Size:

2U (3.5”) x 25” deep

Weight:

50 lbs.

Voltage:

110 or 220 VAC

Ventilation:

Side to side airflow

 

Rear exhaust for power supplies

8.2Operating Environment

Temperature:

32-85 °F (0-30 °C)

Max relative humidity:

80%

(non-condensing)

 

Max heat dissipation:

512 Btu/hr (150 W)

Power consumption:

100-150 W

8.3Non-operating Environment

Temperature:

32-150 °F (0-65 °C)

Relative Humidity:

10-90%

(non-condensing)

 

8.4 Warranty

1 year FOB

Texas Memory Systems, Inc. Houston, Texas

- 26 -

Image 31
Contents Texas Memory SYSTEMS, INC Page Table of Contents Reset Status Figures Document Overview PrefaceConventions Overview IntroductionSystem Components Non-Volatility Power RequirementsPage System Inspection InstallationBattery Warning Electro-Static Discharge WarningRamSan-210 Layout Connecting the Power Supplies Connecting the Fibre Channel PortsRack Mounting On switch Low Voltage Battery System Initialization Turning on the SystemRamSan-210 Front Panel Using the Front PanelMenu System Layout Ethernet SetupManual Shutdown System Monitoring Page Management Control Port MCP Connecting to the MCPConnecting using a terminal program Connecting using telnetExit MCP CommandsHelp Page Manage LunconfigReset RebootStatus Hot Swap Components Hot Swapping Power SuppliesHot Swapping Fans Hot Swapping Disk DrivesPage Batteries Troubleshooting Operating Environment SpecificationsPhysical Characteristics WarrantyFigure B-1 MCP31 Management Control Processor Appendix a RamSan-210 Replacement PartsFigure B-3 PWR21 Power Supply Module Figure B-6 TDD21 18 gigabyte replacement hard drive