Studer Innotec AJ SERIES Maintenance, Warranty limit, Limits of manufacturer liability

Page 7

STUDER INNOTEC

Maintenance

The inverters of the AJ series do not need any special maintenance. The casing may be cleaned with a damp cloth (not wet).

In the case of malfunction, the inverter should be sent back to the manufacturer for control in its original packing.

Before sending the inverter, check the table above.

The battery is loaded and is in accordance to the inlet nominal tension of the device.

The consumer devices do not have any defects or overload for the inverter. Should you contact your salesperson, note the following points before calling: (you will find this information on the label underneath the inverter)

-Series number

-Power of the inverter

-Inlet nominal voltage of the inverter

Before sending back the inverter, do take care that it is well packed. The inverter must be in a stiff carton box and be well protected on all sides by mean of an anti-shock and isolating layer of min. 5cm thickness.

The damages occurring during the transport are not covered by the warranty.

Warranty limit

The warranty period is 2 years.

It will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damage arising from improper use like:

Reverse of battery polarity

Inadequate input voltage (over voltage)

Back-feed of the inverter output by public network, generator or any other source.

Mechanical shock or deformation specially by transport due to an inadequate package.

AJ

Contact with liquid or oxidation by condensation

Use in inappropriate environment (dust, corrosive vapour, humidity, high temperature,...)

This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than STUDER INNOTEC or a company authorised by STUDER INNOTEC. In order to qualify for the warranty, the product must not be disassembled or modified.

Limits of manufacturer liability

STUDER INNOTEC cannot control the installation, use and maintenance of the inverter. Thus, we are not responsible for damages, costs or losses resulting from an installation which is not in accordance with the regulations or inappropriate use or maintenance.

The customer is always responsible for the use of the inverters STUDER INNOTEC.

This device has not been designed and is not warranted for use in life support apparatus or any other critical device with potential risks of important harm to people or to the environment. We do not accept any responsibility for any violation of patent rights or other third person rights resulting from the use of the inverter.

STUDER INNOTEC keeps the right to modify their products without previous notice.

JT8 Remote control for AJ 1000- 2400

Functions on remote control are the same as control and indicator on the inverter (see chapter Use)

Remote control should be connected with the inverter with the original 10m. STUDER cable or

any RJ11/6p 1:1 cable up to max 50m.

AJ V2.1

7/24

Image 7
Contents Page Studer Innotec Introduction InstallationFitting the inverter Check that the cables are well adjusted and well tightened Equivalent schema Connecting the battery Connection Model with stand-by system UseFailure Consequence Solution SafetyLimits of manufacturer liability MaintenanceWarranty limit JT8 Remote control for AJ 1000Studer Innotecaj Technical dataModel Model with built-in solar charger option S Vorsicht EinführungBefestigung des AJ Anschluss Prinzipschema Anschluss der BatterieAnschluss der Verbraucher Grüne Leuchte Akustischer SignalgeberAnwendungen Bedienung und Anzeigen Steuertaste on/offFehler Wirkung Lösung SicherheitenGarantieausschluss UnterhaltHaftungsausschluss Technische Daten JT8 Fernsteuerung für AJModell Anschluss des Solarmodule an AJ 2100/2400-S Solarladeregler für fotovoltaï- sche Solarmodule Option SBraun oder rot = Pluspol + Blau oder Schwarz = Minuspol Lieu de montage de l’onduleur Mise en gardeFixation de l’onduleur Schéma équivalent RaccordementModèles avec stand-by UtilisationSécurités Faute Consequence ResolutionExclusion de la responsabilité Exclusion de la garantieDonnées techniques T8 Commande à distance pour AJModele Raccordement des modules sur AJ 2100/2400-S Modèles avec chargeur solaire option SRoland Studer / Director 2004/04/04 Full name / position Declaration of Conformity