Studer Innotec AJ SERIES manuel dutilisation Technical data, Studer Innotecaj, Model

Page 8

STUDER INNOTECAJ

Technical data

MODEL

AJ 275

 

AJ 350

 

AJ 400

AJ 500

AJ 600

AJ 700

Battery voltage (V)

12

 

24

 

48

12

24

48

Input voltage (V)

10.5 - 16

 

21 - 32

42 - 64

10.5 - 16

21 - 32

42 - 64

Continuous / 30’ power (VA)

200/275

 

300/350

 

300/400

400/500

500/600

500/700

Stand-by / ON @ no load (W)

0.3*/1.9

 

0.3*/3.3

 

0.4*/5

0.3/3.8

0.4/8.5

1/10

Maximum efficiency (%)

93

 

94

 

94

93

94

94

Dim. 142 x 84 x L (mm) L=

 

 

163

 

 

 

240

 

eight (kg)

2.4

 

2.6

 

2.6

 

4.5

 

Remote control plug (RCM-01)

 

 

Option

 

 

 

Option

 

Load detect. (Stand-by) 1-20 W

 

with option S

 

 

V

 

Solar charge controller (-S)

 

 

10A

 

 

15A

 

MODEL

 

AJ 1000

 

AJ 1300

 

 

AJ 2100

 

AJ 2400

Battery voltage (V)

12

 

24

 

12

 

24

Input voltage (V)

10.5 - 16

 

21 - 32

 

10.5 - 16

 

21 - 32

Continuous / 30’ power (VA)

800/1000

 

1000/1300

 

2000/2100

 

2000/2400

Stand-by / ON @ no load (W)

0.3 / 9

 

0.4 / 10

 

0.5 / 13

 

0.4 /18

Maximum efficiency (%)

93

 

94

 

92

 

94

Dim. 142 x 84 x L (mm) L=

 

 

428

 

 

273 x 399 x 117

Weight in kg. (approx.)

 

 

8.5

 

19

 

18

Remote control (JT8)

 

 

Option

 

 

Option

Load detect. (Stand-by) 1-20 W

 

 

v

 

 

V

 

Solar charge controller (-S)

 

 

25A

 

 

30A

 

 

 

 

Sine wave 230V +/-5% (115V +/-5%)

 

Output voltage

 

 

 

Frequency

 

 

50 Hz +/- 0.05 % (60 Hz +/-0.05%)

 

Ventilation

 

 

 

From 45° C

 

Overheating protection

 

 

 

 

v

 

Overload protection

 

 

 

 

v

 

Short circuit protection

 

 

 

 

v

 

IP protection index

 

 

 

IP 30 (AJ 2100-2400 = IP 20)

 

Cos ϕ

 

 

 

 

0.1-1

 

 

E norm (ECE-R 10)

 

 

All models in 12 and 24V are certified

 

* Stand-by supplied along with the option –S (solar charge controller)

AJ V2.1

8/24

Image 8
Contents Page Studer Innotec Fitting the inverter InstallationIntroduction Connection Equivalent schema Connecting the batteryCheck that the cables are well adjusted and well tightened Use Model with stand-by systemSafety Failure Consequence SolutionMaintenance Warranty limitJT8 Remote control for AJ 1000 Limits of manufacturer liabilityModel Technical dataStuder Innotecaj Model with built-in solar charger option S Befestigung des AJ EinführungVorsicht Anschluss der Verbraucher Prinzipschema Anschluss der BatterieAnschluss Akustischer Signalgeber AnwendungenBedienung und Anzeigen Steuertaste on/off Grüne LeuchteSicherheiten Fehler Wirkung LösungHaftungsausschluss UnterhaltGarantieausschluss Modell JT8 Fernsteuerung für AJTechnische Daten Braun oder rot = Pluspol + Blau oder Schwarz = Minuspol Solarladeregler für fotovoltaï- sche Solarmodule Option SAnschluss des Solarmodule an AJ 2100/2400-S Fixation de l’onduleur Mise en gardeLieu de montage de l’onduleur Raccordement Schéma équivalentUtilisation Modèles avec stand-byFaute Consequence Resolution SécuritésExclusion de la garantie Exclusion de la responsabilitéModele T8 Commande à distance pour AJDonnées techniques Modèles avec chargeur solaire option S Raccordement des modules sur AJ 2100/2400-SDeclaration of Conformity Roland Studer / Director 2004/04/04 Full name / position