Setting the Delay Mode for Trunking Mode

A default delay of 2 seconds is automatically set for each talkgroup for ID Scan mode and ID Search mode. To set the delay feature on or off, press DELAY while trunking, “DLY” will appear or disappear depending on your setting.

Trunking Frequency Confirmation

You can check the frequency while a talkgroup ID is active.

Press the key ,and the active frequency on which the talk group is transmitting will flash on the display. Or press and hold the key for 2 seconds, the ID and the frequency alternately appears on the display. To cancel this mode, press the key again.

Hint: This feature is applied to ID Scan mode and ID Search mode.

Setting Priority in Trunking Mode

You can set priority in your Scan lists, just as you do in your conventional ones. Default setting for the Priority ID is the first location in each Scan List. You can set the priority by pressing and holding PRI for 2 seconds in ID Scan Hold mode. After you’ve set up your Scan List, press PRI to activate it.

It’s very similar to conventional priority although there is no "interrupt" during the transmissions. Priorities are checked in between transmissions.

With Priority ON, you can hold on an ID in your Scan List, such as Scan List 3, memory location 7, and the scanner will check all the priorities in all the active Scan Lists in between any transmissions on the ID on which you’re holding. The lowest numbered priority will be checked first. For example, the Priority ID in List 1 will be checked before the Priority in List 2, etc.

Note: • This function does not work in LTR tracking.

Priority Scan does not operate when Priority IDs are locked out.

Moving between Scan List Memories

There are a number of ways to step and move through your Scan List memories:

1.Press HOLD/RESUME in the ID Scan mode and use the or key to move to up or down.

2.Or, press HOLD/RESUME in the ID Scan mode, next press 0-9(scan list number), then press 0-9(memory position). For example to move to Scan List 4, memory position 10, press: HOLD/RESUME, 4, 0, HOLD/RESUME

37

Image 41
Contents Page Precautions Contents Page LTR Introduction8 9 Front and Rear ViewsIcon Display What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Scanner.uniden.com Where to Obtain More InformationInformation on the Internet Included with Your Scanner Package Optional AccessoriesFor Mobile Use In-Car Installation Installing the BCT8For Home Use Desktop Installation Connecting the Power Cord Installation for everyday use Typical Mounting Methods Attach the scanner to the mounting bracket usingMounting the Scanner in Your Vehicle Supplied mounting knobsDC power Installation Applying Power for Vehicle InstallationConnecting an External Speaker Applying Power Using Standard AC PowerConnecting the Clone Cable Listening SafelyTurn the Scanner On Scanning OverviewHow Squelch Works Setting the SquelchScanning Highway Patrol Frequency Highway Patrol ScanningSelecting the State Highway Patrol Scan Hold Alert Tone VolumeHighway Warning Alert Muting the Alert TonePriority Channels Alert Light AdjustmentSkip Frequencies Florida Trunked Highway Frequency Deleting a Stored Frequency Private Bank ScanningProgramming Frequencies into Channels Scanning Private Bank Duplicate Frequency AlertMemory Lock Channel Lockout Restoring a Locked-out Channel in Hold ModeHold/Resume Changing the Priority Channel Restoring All Locked-out ChannelsPriority Scan Service Scanning Band Search Setting a Search BandFrequency Skip Search Hold FeatureData Skip Storing Search Frequencies DelayTrunk Tracking Selecting Trunking System Type Programming Trunking FrequenciesProgramming Talk Group ID/Scan Lists Programming Trunking FrequenciesTo enter a Type 1 ID To enter a Type 2 Talk Group IDTo enter a Full Edacs ID To enter a Partial Edacs IDReceiving Trunked Systems ID Scan ModeTo directly access a specific ID location ID Scan Hold FeatureID Search Mode ID Search Hold and Direct Entry ID in Hold Mode ID Monitor ModeProgramming Scan Lists During Search Deleting a Stored IDTo restore all locked out IDs in a bank once To restore a single ID, follow these stepsID Lockout Review ID LockoutSetting Priority in Trunking Mode Setting the Delay Mode for Trunking ModeTrunking Frequency Confirmation Moving between Scan List MemoriesMulti-Track Operational Details Multi-TrackProgramming Edacs System Frequencies Edacs ReceptionEdacs Tracking An Edacs Trunked system Edacs ID Range Search Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionProgramming a User Fleet Map Selecting Preset Fleet MapFleet Map Programming Programming a Hybrid System Toggling the Status Bit Control Channel Only ModeDisconnect Tone Detect Option End Code Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerScanner.uniden.com PC Control Parameter Clone ModeStart Remote Mode and Change Transfer Speed To connect the Scanner to Scanner If you wish to clone another scanner right away General Use Care and MaintenanceNot receiving alarms Check antenna connections TroubleshootingAdjust the squelch for Trunking mode refer to Specifications State Code Order AppendixPreset Fleet Maps E1P9 Block Type I Programming Information User Defined Fleet MapsFleet Map Size Codes Memo Memo Uniden America Corporation One Year Limited Warranty

BCT-8 specifications

The Uniden BCT-8 is a portable scanner that has made a significant impact in the world of communications monitoring. Designed for both amateur enthusiasts and professional users, this device provides a robust set of features, making it an essential tool for anyone interested in receiving and decoding a wide range of radio frequencies.

One of the standout features of the BCT-8 is its ability to scan both conventional and trunked radio systems. This versatility allows users to listen to everything from local police and fire department communications to amateur radio operations and even aviation channels. The scanner operates between 25 MHz and 1300 MHz, covering a wide array of frequencies that cater to diverse listening interests.

The BCT-8 is equipped with a user-friendly interface, featuring an LCD screen that displays clearly readable information such as channel frequencies and descriptions. Additionally, it utilizes a programmable scan feature, enabling users to store frequencies in memory for quick access. This functionality is particularly useful for those who regularly monitor specific channels, saving time and simplifying the scanning process.

Another notable technology in the BCT-8 is its capability to decode CTCSS and DCS tones, allowing users to filter out unwanted signals and focus on the conversations that matter most to them. This feature is particularly beneficial for monitoring crowded frequencies, ensuring that listeners can hone in on their desired transmissions without interference.

The battery life of the Uniden BCT-8 is also impressive, providing extended use for those on the go. It can operate on AA batteries or a rechargeable battery pack, giving users flexibility depending on their listening habits and requirements.

In terms of build quality, the BCT-8 is sturdy yet compact, making it portable enough to carry during outdoor activities or while traveling. This is complemented by an included belt clip, allowing for hands-free operations, perfect for fieldwork or public safety applications.

Overall, the Uniden BCT-8 stands out for its extensive feature set and reliable performance, making it an ideal choice for individuals who wish to explore the rich world of radio communications. Its combination of advanced scanning capabilities, ease of use, and portability makes it a valuable addition to any scanner enthusiast's toolkit. Whether for personal use or professional monitoring, the BCT-8 excels in delivering comprehensive reception of diverse radio signals.