Uniden BCT-8 manual Adjust the squelch for Trunking mode refer to

Page 58

If you experience difficulty while in TrunkTracker mode, try the following steps.

Problem

 

Suggestion

 

 

 

Scanner won't track.

1.

Missing the Data Frequency.

 

2. Change to a Type 1 Scanner setup.

 

 

Review Fleet Map Programming on page 45.

 

 

Scanner won't stop

1. No IDs have been programmed.

during Scan List mode.

2.

The IDs you have stored are not active.

 

 

Scanner will not acquire

1. Adjust the squelch for Trunking mode - refer to page 29.

data channel.

2.

Missing the frequency used for the data channel.

 

 

Check your frequency list.

 

 

 

Missing replies to

1.

Change a Type 1 scanner setup.

conversations.

 

Review Fleet Map Programming on page 44.

 

2.

Try another Preset Fleet Map or Program your own Fleet Map.

 

3.

Check to see that all of the system's frequencies have been entered.

 

 

 

Channel Activity

1.

May be a telephone interconnect call, which are intentionally blocked by

Indicators are flashing

 

your scanner.

but no sound is heard.

2.

The ID on your display is not active.

 

 

 

Scanner not tracking an

1.

Logical channel numbers (frequencies) for the system are not programmed

EDACS system properly.

 

in the correct order. Check frequency resources and reprogram.

 

2.

Not all frequencies for the system are programmed.

 

 

Check frequency resources.

 

 

 

If you still cannot get satisfactory results while using your scanner or if you want additional information, please call or write the Uniden Parts and Service Division. The address and phone number is listed in the warranty at the end of this manual. If you would like immediate assistance, please call Customer Service at (800)297-1023.

If you have internet access, you can visit scanner.uniden.com for additional information.

54

Image 58
Contents Page Precautions Contents Page Introduction LTRFront and Rear Views 8 9Icon Display What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Information on the Internet Where to Obtain More InformationScanner.uniden.com Optional Accessories Included with Your Scanner PackageFor Home Use Desktop Installation Installing the BCT8For Mobile Use In-Car Installation Connecting the Power Cord Installation for everyday use Mounting the Scanner in Your Vehicle Attach the scanner to the mounting bracket usingTypical Mounting Methods Supplied mounting knobsApplying Power for Vehicle Installation DC power InstallationConnecting the Clone Cable Applying Power Using Standard AC PowerConnecting an External Speaker Listening SafelyScanning Overview Turn the Scanner OnSetting the Squelch How Squelch WorksSelecting the State Highway Patrol ScanningScanning Highway Patrol Frequency Highway Warning Alert Alert Tone VolumeHighway Patrol Scan Hold Muting the Alert ToneSkip Frequencies Alert Light AdjustmentPriority Channels Florida Trunked Highway Frequency Programming Frequencies into Channels Private Bank ScanningDeleting a Stored Frequency Memory Lock Duplicate Frequency AlertScanning Private Bank Hold/Resume Restoring a Locked-out Channel in Hold ModeChannel Lockout Priority Scan Restoring All Locked-out ChannelsChanging the Priority Channel Service Scanning Setting a Search Band Band SearchData Skip Search Hold FeatureFrequency Skip Delay Storing Search FrequenciesTrunk Tracking Programming Trunking Frequencies Selecting Trunking System TypeProgramming Trunking Frequencies Programming Talk Group ID/Scan ListsTo enter a Full Edacs ID To enter a Type 2 Talk Group IDTo enter a Type 1 ID To enter a Partial Edacs IDID Scan Mode Receiving Trunked SystemsID Search Mode ID Scan Hold FeatureTo directly access a specific ID location Programming Scan Lists During Search ID Monitor ModeID Search Hold and Direct Entry ID in Hold Mode Deleting a Stored IDID Lockout To restore a single ID, follow these stepsTo restore all locked out IDs in a bank once Review ID LockoutTrunking Frequency Confirmation Setting the Delay Mode for Trunking ModeSetting Priority in Trunking Mode Moving between Scan List MemoriesMulti-Track Multi-Track Operational DetailsEdacs Tracking Edacs ReceptionProgramming Edacs System Frequencies An Edacs Trunked system Special Edacs Features Edacs ID Range SearchLTR Reception LTR TrackingMotorola Reception Motorola TrackingFleet Map Programming Selecting Preset Fleet MapProgramming a User Fleet Map Programming a Hybrid System Control Channel Only Mode Toggling the Status BitDisconnect Tone Detect Option End Code To connect Scanner to PC PC Control ModeRemote Interface To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeScanner.uniden.com PC Control Parameter To connect the Scanner to Scanner If you wish to clone another scanner right away Care and Maintenance General UseTroubleshooting Not receiving alarms Check antenna connectionsAdjust the squelch for Trunking mode refer to Specifications Appendix State Code OrderPreset Fleet Maps E1P9 Block User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Memo Memo One Year Limited Warranty Uniden America Corporation

BCT-8 specifications

The Uniden BCT-8 is a portable scanner that has made a significant impact in the world of communications monitoring. Designed for both amateur enthusiasts and professional users, this device provides a robust set of features, making it an essential tool for anyone interested in receiving and decoding a wide range of radio frequencies.

One of the standout features of the BCT-8 is its ability to scan both conventional and trunked radio systems. This versatility allows users to listen to everything from local police and fire department communications to amateur radio operations and even aviation channels. The scanner operates between 25 MHz and 1300 MHz, covering a wide array of frequencies that cater to diverse listening interests.

The BCT-8 is equipped with a user-friendly interface, featuring an LCD screen that displays clearly readable information such as channel frequencies and descriptions. Additionally, it utilizes a programmable scan feature, enabling users to store frequencies in memory for quick access. This functionality is particularly useful for those who regularly monitor specific channels, saving time and simplifying the scanning process.

Another notable technology in the BCT-8 is its capability to decode CTCSS and DCS tones, allowing users to filter out unwanted signals and focus on the conversations that matter most to them. This feature is particularly beneficial for monitoring crowded frequencies, ensuring that listeners can hone in on their desired transmissions without interference.

The battery life of the Uniden BCT-8 is also impressive, providing extended use for those on the go. It can operate on AA batteries or a rechargeable battery pack, giving users flexibility depending on their listening habits and requirements.

In terms of build quality, the BCT-8 is sturdy yet compact, making it portable enough to carry during outdoor activities or while traveling. This is complemented by an included belt clip, allowing for hands-free operations, perfect for fieldwork or public safety applications.

Overall, the Uniden BCT-8 stands out for its extensive feature set and reliable performance, making it an ideal choice for individuals who wish to explore the rich world of radio communications. Its combination of advanced scanning capabilities, ease of use, and portability makes it a valuable addition to any scanner enthusiast's toolkit. Whether for personal use or professional monitoring, the BCT-8 excels in delivering comprehensive reception of diverse radio signals.