Uniden BC296D manual

Page 15

Logical Channel Numbers – each frequency used by the system is assigned an LCN. This information is programmed into each user radio. When a user presses PTT, their radio sends their AFS information to the control channel. The computer then assigns that talkgroup to a channel and sends the LCN so that all other radios in that talkgroup will switch to the correct channel. To program a EDACS system in your scanner, you will need to know both the frequencies used by the system and the LCN for each frequency so that you can program the frequencies in LCN order.

Agency-Fleet-Subfleet– talkgroup ID’s for EDACS systems are assigned in a way that makes it easy to see at a glance the affiliation of the user. Each radio is assigned a 2-digit agency identifier from 00 – 15. For example, 01 might be used by the police, 02 by ambulance service, 03 by the fire department, and so on. Each agency is then subdivided up to 16 times to provide fleet identification, and then 8 more times to identify subfleets.

For example, the complete AFS for the Police Department West District’s dispatch channel might be 01-062. 01 identifies the agency as the police department, 06 identifies the fleet as the West district, and 02 identifies the subfleet as the dispatch channel. While these assignments are somewhat arbitrary and vary from system to system, there are many resources on the web for finding the assignments for most systems.

Because of the logical hierarchy of the AFS system, your BC296D lets you assign wildcard ID’s that let you, for example, use only one ID memory to identify all units in either an agency or a fleet.

EDACS SCAT – EDACS SCAT (Single Channel Autonomous Trunking) systems operate on a single channel and alternate control data with analog voice traffic. While your BC296D cannot track ID’s in this system, it can eliminate the control data so that all you hear is the voice transmissions when you monitor this type of system.

9

Image 15
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Repeater Operation Understanding ScanningConventional Scanning Simplex OperationTrunked Scanning Edacs Trunking Page LTR Trunking Understanding Banks and ChannelsGetting More Information Buttons and Controls Quick Look at Your ScannerIcon Description Display IconsIncluded With Your Scanner Setting Up Your Scanner Installing the Battery PackCharging the Battery Pack Using Headphones or an External Speaker Nickel-Metal Hydride Battery DisposalInstalling the Antenna Installing the Belt ClipListening Safely Setting the Squelch Basic OperationTurning On the Scanner Manually Selecting a Channel Using the MenuRestoring All Locked Out Channels Scanning Programmed ChannelsLocking/Unlocking Banks Locking/Unlocking ChannelsPriority Scanning Priority Plus ScanningListening to the Input Channel Controlling How Much Information Appears Using the BacklightDimmer Light Setting Dimmer Time SettingDisabling the APCO25 Card Turning the Key Beep On/OffLocking the Enter key Locking the KeypadTurning Battery Save On/Off Setting Squelch ModeMuting All Audio Monitoring Talkgroup ID’s Trunk Scanning OptionsSearching for Active Talkgroups ID Search Scanning Only Stored Talkgroups ID ScanHolding on a Single Talkgroup Locking Out TalkgroupsEdacs Blockout Edacs Patch Tracking Unlocking All TalkgroupsHolding on an Active Frequency Setting Chain SearchSetting Data Skip SearchingStoring Found Frequencies Skipping FrequenciesSetting Subaudible Tones for Searching Automatically Storing FrequenciesSearching for Subaudible Tones Setting Delay for All Search Ranges Setting a Search RangeAttenuating All Search Ranges Searching for Trunk Systems Service Search Skip Service SearchUsing Weather Search and Weather Alert Same Using Weather Alert SameSearching for a Weather Broadcast Dssccc Testing the Weather Alert Bank Configuration Programming Bank InformationAssigning Bank Names Entering Alpha Information General ProgrammingDeleting Frequencies from Channels Transferring Channel InformationPage Programming Conventional Channels Select a Channel to ProgramEnter the Frequency Setting the Delay Setting the Subaudible Tone OptionAssigning a Text Tag Setting the Attenuator Setting Beep AlertChanging the Frequency Step Setting the Modulation ModeSetting Priority Channels Programming Trunked Systems Setting Trunking Delay Using I-Call Motorola and Edacs onlyTurning I-Call On and Off for ID Search Setting Priority Talkgroups Motorola and Edacs only Multi-TrackTurning I-Call On for ID Scan Multi-Track Operational Details Programming Motorola Systems Using Control Channel ProgrammingProgramming Type2/Digital VHF and UHF Systems Programming Type 2/Digital 800 and 900 MHz SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Channels Programming Edacs SystemsSetting Edacs Decimal Mode Setting Edacs Emergency AlertProgramming Apco Systems Setting Apco 25 Sound QualityPage Programming LTR Systems Press MENU/BACK Programming TalkgroupsStoring Known Talkgroups Storing Found TalkgroupsDeleting Stored Talkgroup ID’s Adding a Text Tag to an ID ListSeeing Talkgroup Activity Using the Remote Interface PC Control ModeCloning Scanner Settings Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Uniden America Corporation One Year Limited Warranty