Uniden BC296D manual Assigning a Text Tag, Setting the Delay, Setting the Subaudible Tone Option

Page 47

3. Assigning a Text Tag

a.Use the scroll bar to select the channel you want to tag, then press E.

b.Use the scroll bar to select the letter, then press RSM to move the entry position one space to the right or press HOLD/MAN to move the entry position one space to the left.

c.When you have entered the tag, press E to save the tag.

The scanner displays

1:OTHER CHANNEL

Select to pick another channel to program from Step 1

2:CHANNEL OPTION

Select to set additional channel options (see the following sections).

3:DONE

Exit the channel setting and menu mode.

Setting the Delay

2:SCAN OPTION 1:CONVENTIONAL → Channel No. → 2:DELAY

The delay option lets you set a 2-second delay after a transmission for each channel. This slows down scanning, but helps to prevent missing replies.

1:ON

Turn on the delay for the channel

2:OFF

Turn off the delay

Setting the Subaudible Tone Option

2:SCAN OPTION 1:CONVENTIONAL → Channel No. → 3:TONE DATA

Some radio systems use special tones to prevent interference from other nearby systems operating on the same frequencies. When tones are being used, the radios only open squelch when a transmission with a matching tone is present on the frequency. Some services, such as FRS, GMRS, and Business Band refer to these tones as Quiet Codes, Privacy Codes, or similar and use a number to associate a particular tone. The table in the back of the manual provides a cross reference to common associations. For this feature to work, you need to turn on the Tone Mode (see “Setting Squelch Mode”).

41

Image 47
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Repeater Operation Understanding ScanningConventional Scanning Simplex OperationTrunked Scanning Edacs Trunking Page LTR Trunking Understanding Banks and ChannelsGetting More Information Buttons and Controls Quick Look at Your ScannerIcon Description Display IconsIncluded With Your Scanner Charging the Battery Pack Setting Up Your ScannerInstalling the Battery Pack Using Headphones or an External Speaker Nickel-Metal Hydride Battery DisposalInstalling the Antenna Installing the Belt ClipListening Safely Turning On the Scanner Setting the SquelchBasic Operation Manually Selecting a Channel Using the MenuRestoring All Locked Out Channels Scanning Programmed ChannelsLocking/Unlocking Banks Locking/Unlocking ChannelsListening to the Input Channel Priority ScanningPriority Plus Scanning Controlling How Much Information Appears Using the BacklightDimmer Light Setting Dimmer Time SettingDisabling the APCO25 Card Turning the Key Beep On/OffLocking the Enter key Locking the KeypadMuting All Audio Turning Battery Save On/OffSetting Squelch Mode Monitoring Talkgroup ID’s Trunk Scanning OptionsSearching for Active Talkgroups ID Search Scanning Only Stored Talkgroups ID ScanEdacs Blockout Holding on a Single TalkgroupLocking Out Talkgroups Edacs Patch Tracking Unlocking All TalkgroupsHolding on an Active Frequency Setting Chain SearchSetting Data Skip SearchingStoring Found Frequencies Skipping FrequenciesSearching for Subaudible Tones Setting Subaudible Tones for SearchingAutomatically Storing Frequencies Attenuating All Search Ranges Setting Delay for All Search RangesSetting a Search Range Searching for Trunk Systems Service Search Skip Service SearchSearching for a Weather Broadcast Using Weather Search and Weather Alert SameUsing Weather Alert Same Dssccc Testing the Weather Alert Assigning Bank Names Bank ConfigurationProgramming Bank Information Entering Alpha Information General ProgrammingDeleting Frequencies from Channels Transferring Channel InformationPage Enter the Frequency Programming Conventional ChannelsSelect a Channel to Program Assigning a Text Tag Setting the DelaySetting the Subaudible Tone Option Setting the Attenuator Setting Beep AlertChanging the Frequency Step Setting the Modulation ModeSetting Priority Channels Programming Trunked Systems Turning I-Call On and Off for ID Search Setting Trunking DelayUsing I-Call Motorola and Edacs only Turning I-Call On for ID Scan Setting Priority Talkgroups Motorola and Edacs onlyMulti-Track Multi-Track Operational Details Programming Motorola Systems Using Control Channel ProgrammingProgramming Type2/Digital VHF and UHF Systems Programming Type 2/Digital 800 and 900 MHz SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Channels Programming Edacs SystemsSetting Edacs Decimal Mode Setting Edacs Emergency AlertProgramming Apco Systems Setting Apco 25 Sound QualityPage Programming LTR Systems Press MENU/BACK Programming TalkgroupsStoring Known Talkgroups Storing Found TalkgroupsSeeing Talkgroup Activity Deleting Stored Talkgroup ID’sAdding a Text Tag to an ID List Cloning Scanner Settings Using the Remote InterfacePC Control Mode Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Uniden America Corporation One Year Limited Warranty