Uniden BC296D manual Automatically Storing Frequencies, Setting Subaudible Tones for Searching

Page 36

Automatically Storing Frequencies

During searching, you can have the scanner automatically store active frequencies into a bank you choose.

1:SERVICE OPTION :CHAIN SEARCH 6:AUTO STORE 1:ON

1.Press the numbers corresponding to the banks you want the scanner to store found frequencies into.

2.Press SEARCH to start the auto-store operation.

3.Press HOLD/MAN to stop auto-store. The scanner exits the auto-store mode.

Note: To ensure that you catch most active frequencies for the band, you should allow the auto-store operation to continue through at least a few complete sweeps of the band. Depending on the types of services, some occasionally active frequencies might not have activity for minutes or hours at a time.

Setting Subaudible Tones for Searching

You can set the scanner to only stop on transmissions that either have no subaudible tone or include a specified CTCSS or DCS tone during searches. This setting affects all search ranges. For this feature to work, you need to turn on the Tone Mode (see “Setting Squelch Mode”).

1:SERVICE OPTION :CHAIN SEARCH 5:TONE DATA

1:CTCSS

Lets you set the CTCSS tone.

2:DCS

Lets you set the DCS.

3:OFF

Does not use subaudible tones.

Note: If, instead of pressing E to select a tone you press L/O, the scanner will stop on any transmission except for those with the selected tone.

Searching for Subaudible Tones

If you set the system tone option to 3:TONE SEARCH (see “Setting Squelch Mode”), the scanner will determine the correct tone for the received signal.

30

Image 36
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Understanding Scanning Conventional ScanningSimplex Operation Repeater OperationTrunked Scanning Edacs Trunking Page Understanding Banks and Channels LTR TrunkingGetting More Information Quick Look at Your Scanner Buttons and ControlsDisplay Icons Icon DescriptionIncluded With Your Scanner Setting Up Your Scanner Installing the Battery PackCharging the Battery Pack Nickel-Metal Hydride Battery Disposal Installing the AntennaInstalling the Belt Clip Using Headphones or an External SpeakerListening Safely Setting the Squelch Basic OperationTurning On the Scanner Using the Menu Manually Selecting a ChannelScanning Programmed Channels Locking/Unlocking BanksLocking/Unlocking Channels Restoring All Locked Out ChannelsPriority Scanning Priority Plus ScanningListening to the Input Channel Using the Backlight Dimmer Light SettingDimmer Time Setting Controlling How Much Information AppearsTurning the Key Beep On/Off Locking the Enter keyLocking the Keypad Disabling the APCO25 CardTurning Battery Save On/Off Setting Squelch ModeMuting All Audio Trunk Scanning Options Searching for Active Talkgroups ID SearchScanning Only Stored Talkgroups ID Scan Monitoring Talkgroup ID’sHolding on a Single Talkgroup Locking Out TalkgroupsEdacs Blockout Unlocking All Talkgroups Edacs Patch TrackingSetting Chain Search Setting Data SkipSearching Holding on an Active FrequencySkipping Frequencies Storing Found FrequenciesSetting Subaudible Tones for Searching Automatically Storing FrequenciesSearching for Subaudible Tones Setting Delay for All Search Ranges Setting a Search RangeAttenuating All Search Ranges Searching for Trunk Systems Service Search Service Search SkipUsing Weather Search and Weather Alert Same Using Weather Alert SameSearching for a Weather Broadcast Dssccc Testing the Weather Alert Bank Configuration Programming Bank InformationAssigning Bank Names General Programming Deleting Frequencies from ChannelsTransferring Channel Information Entering Alpha InformationPage Programming Conventional Channels Select a Channel to ProgramEnter the Frequency Setting the Delay Setting the Subaudible Tone OptionAssigning a Text Tag Setting Beep Alert Setting the AttenuatorSetting the Modulation Mode Changing the Frequency StepSetting Priority Channels Programming Trunked Systems Setting Trunking Delay Using I-Call Motorola and Edacs onlyTurning I-Call On and Off for ID Search Setting Priority Talkgroups Motorola and Edacs only Multi-TrackTurning I-Call On for ID Scan Multi-Track Operational Details Using Control Channel Programming Programming Motorola SystemsProgramming Type 2/Digital 800 and 900 MHz Systems Programming Type2/Digital VHF and UHF SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Systems Programming Edacs ChannelsSetting Edacs Emergency Alert Setting Edacs Decimal ModeSetting Apco 25 Sound Quality Programming Apco SystemsPage Programming LTR Systems Programming Talkgroups Storing Known TalkgroupsStoring Found Talkgroups Press MENU/BACKDeleting Stored Talkgroup ID’s Adding a Text Tag to an ID ListSeeing Talkgroup Activity Using the Remote Interface PC Control ModeCloning Scanner Settings Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Preset Fleet Maps AppendixPreset Map Block User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask One Year Limited Warranty Uniden America Corporation