Uniden BC296D manual Basic Operation, Turning On the Scanner, Setting the Squelch

Page 24

Basic Operation

This section is your main reference for using the scanner once you have programmed conventional and trunked systems. Note that there are some slight differences to some functions depending on whether you are trying to affect conventional operation or trunked operation. Be sure to refer to the appropriate section depending on the mode you are using.

Turning On the Scanner

Turn the VOL (VOLUME) control clockwise out of the detent position. The scanner automatically starts scanning. Since there are no frequencies programmed in your scanner initially, you may not receive any signals. Once you set the squelch and program some frequencies, you will begin hearing conversations regularly.

Setting the Squelch

To set the squelch, you must be in the hold mode, and you should not be receiving a

signal on your scanner.

1.Press HOLD/MAN until you do not hear a signal.

2.Make sure that the VOL (VOLUME) is set to a comfortable listening level.

STRONG SIGNALS

MEDIUM SIGNALS

WEAK SIGNALS

NOISE

3.Think of the Squelch Control as a gate. Turn the SQUELCH control fully counterclockwise. This raises the “Squelch Gate” so high that only very strong signals can get through.

4.Turn SQUELCH clockwise until you hear a hiss. This lowers the “Squelch Gate” so that everything gets through – noise, weak signals, medium signals and strong signals.

STRONG SIGNALS

MEDIUM SIGNALS

WEAK SIGNALS

NOISE

STRONG SIGNALS

MEDIUM SIGNALS

WEAK SIGNALS

NOISE

18

Image 24
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Understanding Scanning Conventional ScanningSimplex Operation Repeater OperationTrunked Scanning Edacs Trunking Page Understanding Banks and Channels LTR TrunkingGetting More Information Quick Look at Your Scanner Buttons and ControlsDisplay Icons Icon DescriptionIncluded With Your Scanner Setting Up Your Scanner Installing the Battery Pack Charging the Battery Pack Nickel-Metal Hydride Battery Disposal Installing the AntennaInstalling the Belt Clip Using Headphones or an External SpeakerListening Safely Setting the Squelch Basic OperationTurning On the Scanner Using the Menu Manually Selecting a ChannelScanning Programmed Channels Locking/Unlocking BanksLocking/Unlocking Channels Restoring All Locked Out ChannelsPriority Scanning Priority Plus ScanningListening to the Input Channel Using the Backlight Dimmer Light SettingDimmer Time Setting Controlling How Much Information AppearsTurning the Key Beep On/Off Locking the Enter keyLocking the Keypad Disabling the APCO25 CardTurning Battery Save On/Off Setting Squelch ModeMuting All Audio Trunk Scanning Options Searching for Active Talkgroups ID SearchScanning Only Stored Talkgroups ID Scan Monitoring Talkgroup ID’sHolding on a Single Talkgroup Locking Out TalkgroupsEdacs Blockout Unlocking All Talkgroups Edacs Patch TrackingSetting Chain Search Setting Data SkipSearching Holding on an Active FrequencySkipping Frequencies Storing Found FrequenciesSetting Subaudible Tones for Searching Automatically Storing FrequenciesSearching for Subaudible Tones Setting Delay for All Search Ranges Setting a Search RangeAttenuating All Search Ranges Searching for Trunk Systems Service Search Service Search SkipUsing Weather Search and Weather Alert Same Using Weather Alert SameSearching for a Weather Broadcast Dssccc Testing the Weather Alert Bank Configuration Programming Bank InformationAssigning Bank Names General Programming Deleting Frequencies from ChannelsTransferring Channel Information Entering Alpha InformationPage Programming Conventional Channels Select a Channel to ProgramEnter the Frequency Setting the Delay Setting the Subaudible Tone OptionAssigning a Text Tag Setting Beep Alert Setting the AttenuatorSetting the Modulation Mode Changing the Frequency StepSetting Priority Channels Programming Trunked Systems Setting Trunking Delay Using I-Call Motorola and Edacs onlyTurning I-Call On and Off for ID Search Setting Priority Talkgroups Motorola and Edacs only Multi-TrackTurning I-Call On for ID Scan Multi-Track Operational Details Using Control Channel Programming Programming Motorola SystemsProgramming Type 2/Digital 800 and 900 MHz Systems Programming Type2/Digital VHF and UHF SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Systems Programming Edacs ChannelsSetting Edacs Emergency Alert Setting Edacs Decimal ModeSetting Apco 25 Sound Quality Programming Apco SystemsPage Programming LTR Systems Programming Talkgroups Storing Known TalkgroupsStoring Found Talkgroups Press MENU/BACKDeleting Stored Talkgroup ID’s Adding a Text Tag to an ID ListSeeing Talkgroup Activity Using the Remote Interface PC Control ModeCloning Scanner Settings Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Preset Fleet Maps AppendixPreset Map Block User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask One Year Limited Warranty Uniden America Corporation