Uniden BC296D manual Using the Remote Interface, PC Control Mode, Cloning Scanner Settings

Page 67

Using the Remote

Interface

You can connect your scanner to either a PC or another BC296D using the remote interface cable port. This allows you to either control and program your scanner using a PC and the supplied software and cable or clone the memory from one BC296D into another BC296D (gender changer/coupler required, not supplied).

PC Control Mode

CH/

FRQ

HOLD/

MAN

RSM

SCAN SERVICE SEARCH

MENU/BACK

TRUNK

L/O

REVERSESELECT

.E

To connect the Scanner to a PC, plug the scanner end of the supplied RS232C cable into the remote port which is on the side of the scanner. Plug the other end of the cable into your PC’s serial port.

Start the remote mode and set the scanner’s communications speed:

3:SYSTEM OPTION 5:PC CONTROL

To use PC control, set the scanner to any setting other than off. You will usually want to set the speed to its highest setting. If you seem to be having communications problems between the scanner and PC, set this setting to a lower value.

Cloning Scanner Settings

You will need to purchase an RS232C null modem adapter/gender changer to connect your scanners together. (These items are available at your local electronics stores.)

To connect the Scanners together, plug the scanner ends of the cables into the scanners, then connect the PC ends of the cables to the null modem adapter/gender changer

Clone all of the programming of one BC296D into another, by selecting:

61

Image 67
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Repeater Operation Understanding ScanningConventional Scanning Simplex OperationTrunked Scanning Edacs Trunking Page LTR Trunking Understanding Banks and ChannelsGetting More Information Buttons and Controls Quick Look at Your ScannerIcon Description Display IconsIncluded With Your Scanner Installing the Battery Pack Setting Up Your ScannerCharging the Battery Pack Using Headphones or an External Speaker Nickel-Metal Hydride Battery DisposalInstalling the Antenna Installing the Belt ClipListening Safely Basic Operation Setting the SquelchTurning On the Scanner Manually Selecting a Channel Using the MenuRestoring All Locked Out Channels Scanning Programmed ChannelsLocking/Unlocking Banks Locking/Unlocking ChannelsPriority Plus Scanning Priority ScanningListening to the Input Channel Controlling How Much Information Appears Using the BacklightDimmer Light Setting Dimmer Time SettingDisabling the APCO25 Card Turning the Key Beep On/OffLocking the Enter key Locking the KeypadSetting Squelch Mode Turning Battery Save On/OffMuting All Audio Monitoring Talkgroup ID’s Trunk Scanning OptionsSearching for Active Talkgroups ID Search Scanning Only Stored Talkgroups ID ScanLocking Out Talkgroups Holding on a Single TalkgroupEdacs Blockout Edacs Patch Tracking Unlocking All TalkgroupsHolding on an Active Frequency Setting Chain SearchSetting Data Skip SearchingStoring Found Frequencies Skipping FrequenciesAutomatically Storing Frequencies Setting Subaudible Tones for SearchingSearching for Subaudible Tones Setting a Search Range Setting Delay for All Search RangesAttenuating All Search Ranges Searching for Trunk Systems Service Search Skip Service SearchUsing Weather Alert Same Using Weather Search and Weather Alert SameSearching for a Weather Broadcast Dssccc Testing the Weather Alert Programming Bank Information Bank ConfigurationAssigning Bank Names Entering Alpha Information General ProgrammingDeleting Frequencies from Channels Transferring Channel InformationPage Select a Channel to Program Programming Conventional ChannelsEnter the Frequency Setting the Subaudible Tone Option Setting the DelayAssigning a Text Tag Setting the Attenuator Setting Beep AlertChanging the Frequency Step Setting the Modulation ModeSetting Priority Channels Programming Trunked Systems Using I-Call Motorola and Edacs only Setting Trunking DelayTurning I-Call On and Off for ID Search Multi-Track Setting Priority Talkgroups Motorola and Edacs onlyTurning I-Call On for ID Scan Multi-Track Operational Details Programming Motorola Systems Using Control Channel ProgrammingProgramming Type2/Digital VHF and UHF Systems Programming Type 2/Digital 800 and 900 MHz SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Channels Programming Edacs SystemsSetting Edacs Decimal Mode Setting Edacs Emergency AlertProgramming Apco Systems Setting Apco 25 Sound QualityPage Programming LTR Systems Press MENU/BACK Programming TalkgroupsStoring Known Talkgroups Storing Found TalkgroupsAdding a Text Tag to an ID List Deleting Stored Talkgroup ID’sSeeing Talkgroup Activity PC Control Mode Using the Remote InterfaceCloning Scanner Settings Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Uniden America Corporation One Year Limited Warranty