Uniden BC296D manual

Page 75

Key Beep - This is another term for the tone you hear as a keypad acknowledgement beep. The default setting is on. If you have turned the Key Beep off, you now have a silent keypad. You will not hear a tone each time you press a key.

NWR S.A.M.E. Weather Alert - In 1994, the National Oceanic and Atmospheric Administration (NOAA) began broadcasting coded signals called FIPS (Federal Information Processing System) codes along with the standard weather broadcasts for stations in your area. These codes identify an emergency and the specific geographic area (such as your county) affected by the emergency. The scanner was developed with SAME (Specific Area Messaging Encoding) technology.

This allows you scanner to receive, interpret, and display the information about the codes so you can determine if the emergency might affect you area.Each FIPS code identifies a specific geographic area (defined by the National Weather Service) so your scanner sounds an alert only when a weather emergency is declared in those locations.

This helps you more efficiently track the weather conditions in and around your area.

PC Control - This term is associated with the ability to program frequencies and other useful information via a computer by means of third party software. You can change the transfer speed on the scanner needed to be compatible with your PC. (See page 61)

Scan List - When you designate a bank to be a trunking bank, your scanner sets up 10 Scan Lists, which are simply list of your favorite IDs. Each list can contain up to 10 IDs, so you can store a total of 100 IDs for each trunk bank. These lists are designed to help you organize the trunking system users into categories.

Screen Mask - Screen Mask reduces the amount of information that appears on the display. Alpha tags that you have set for a channel along with a few function icons will appear only on the display. This mode is particularly useful in public safety vehicles where that are already overloaded with information. Screen Mask does not work in Search mode.

Status Bit - This term refers to Motorola Type II systems. There is a method by which special types of communications utilize unique talk group numbers.

For example, if all emergency calls are set to occur on a specific talk group number then you will not miss the transmission even if you have not programmed all the talk group numbers. With the Status Bit on and you have programmed the unique number, then you don’t have to

69

Image 75
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Repeater Operation Understanding ScanningConventional Scanning Simplex OperationTrunked Scanning Edacs Trunking Page LTR Trunking Understanding Banks and ChannelsGetting More Information Buttons and Controls Quick Look at Your ScannerIcon Description Display IconsIncluded With Your Scanner Setting Up Your Scanner Installing the Battery PackCharging the Battery Pack Using Headphones or an External Speaker Nickel-Metal Hydride Battery DisposalInstalling the Antenna Installing the Belt ClipListening Safely Setting the Squelch Basic OperationTurning On the Scanner Manually Selecting a Channel Using the MenuRestoring All Locked Out Channels Scanning Programmed ChannelsLocking/Unlocking Banks Locking/Unlocking ChannelsPriority Scanning Priority Plus ScanningListening to the Input Channel Controlling How Much Information Appears Using the BacklightDimmer Light Setting Dimmer Time SettingDisabling the APCO25 Card Turning the Key Beep On/OffLocking the Enter key Locking the KeypadTurning Battery Save On/Off Setting Squelch ModeMuting All Audio Monitoring Talkgroup ID’s Trunk Scanning OptionsSearching for Active Talkgroups ID Search Scanning Only Stored Talkgroups ID ScanHolding on a Single Talkgroup Locking Out TalkgroupsEdacs Blockout Edacs Patch Tracking Unlocking All TalkgroupsHolding on an Active Frequency Setting Chain SearchSetting Data Skip SearchingStoring Found Frequencies Skipping FrequenciesSetting Subaudible Tones for Searching Automatically Storing FrequenciesSearching for Subaudible Tones Setting Delay for All Search Ranges Setting a Search RangeAttenuating All Search Ranges Searching for Trunk Systems Service Search Skip Service SearchUsing Weather Search and Weather Alert Same Using Weather Alert SameSearching for a Weather Broadcast Dssccc Testing the Weather Alert Bank Configuration Programming Bank InformationAssigning Bank Names Entering Alpha Information General ProgrammingDeleting Frequencies from Channels Transferring Channel InformationPage Programming Conventional Channels Select a Channel to ProgramEnter the Frequency Setting the Delay Setting the Subaudible Tone OptionAssigning a Text Tag Setting the Attenuator Setting Beep AlertChanging the Frequency Step Setting the Modulation ModeSetting Priority Channels Programming Trunked Systems Setting Trunking Delay Using I-Call Motorola and Edacs onlyTurning I-Call On and Off for ID Search Setting Priority Talkgroups Motorola and Edacs only Multi-TrackTurning I-Call On for ID Scan Multi-Track Operational Details Programming Motorola Systems Using Control Channel ProgrammingProgramming Type2/Digital VHF and UHF Systems Programming Type 2/Digital 800 and 900 MHz SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Channels Programming Edacs SystemsSetting Edacs Decimal Mode Setting Edacs Emergency AlertProgramming Apco Systems Setting Apco 25 Sound QualityPage Programming LTR Systems Press MENU/BACK Programming TalkgroupsStoring Known Talkgroups Storing Found TalkgroupsDeleting Stored Talkgroup ID’s Adding a Text Tag to an ID ListSeeing Talkgroup Activity Using the Remote Interface PC Control ModeCloning Scanner Settings Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Uniden America Corporation One Year Limited Warranty