Uniden BC296D manual Specifications

Page 72

Specifications

Certified in accordance with FCC Rules and Regulations Part 15, Subpart C, as of date of manufacture.

Channel:

1000

 

Banks:

10 (100 channels each)

 

Service Bands:

12 preprogrammed search bands

 

(including the NOAA Weather

 

Service band)

 

Frequency Range:

25.0 - 27.995 MHz

AM

 

28.0 - 53.99 MHz

FM

 

54.0 - 71.95 MHz

WFM

 

72.0 - 75.995 MHz

FM

 

76.0 - 87.95 MHz

WFM

 

88.0 - 107.9 MHz

WFM

 

108.0 - 136.975 MHz

AM

 

137.0 - 161.995 MHz

FM

 

162.0 - 173.9875 MHz

FM

 

174.0 - 215.95 MHz

WFM

 

216.0 - 224.995 MHz

FM

 

225.0 - 399.95 MHz

AM

 

400.0 - 512.0 MHz

NFM

 

806.0 - 823.9875 MHz

NFM

 

849.0125 - 868.9875 MHz

NFM

 

894.0125 - 956.0 MHz

NFM

 

1240.0 - 1300.0 MHz

NFM

Operating Temperature:

–20 °C to +60 °C (–4°F to 140°F)

Scan Rate:

100 channels per second MAX.

 

(conventional mode)

 

Search Rate:

100 steps per second MAX.

 

 

(Normal Search)

 

 

300 steps per second MAX.

 

 

(Turbo Search)

 

Scan Delay:

2 seconds

 

Audio Output:

240 mW nominal

 

 

(8Ω internal speaker)

 

 

38 mW nominal

 

 

(32Ω stereo headphone)

 

 

9 mW nominal

 

 

(64Ω earphone)

 

Internal Speaker:

8 ohms (36 mm outer diameter)

Power Requirements:

AD600U AC Adapter

 

 

(12V DC, 500mA)

 

 

or

 

 

4.8V DC 1500mAh (internal battery)

Antenna:

Rubber Antenna (included)

 

Antenna Jack:

BNC type

 

External Jacks:

DC 12 V Power Jack

 

 

(center is positive)

 

 

Remote Jack

 

 

Earphone Jack

 

Size:

65mm (W) x 45mm (D) x 153mm (H)

Weight:

350 g (12 3/8 oz.)

 

Features and specifications are all subject to change without notice.

66

Image 72
Contents Page Page Contents Searching PC Control Mode Cloning Scanner Settings Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Understanding Scanning Conventional ScanningSimplex Operation Repeater OperationTrunked Scanning Edacs Trunking Page Understanding Banks and Channels LTR TrunkingGetting More Information Quick Look at Your Scanner Buttons and ControlsDisplay Icons Icon DescriptionIncluded With Your Scanner Setting Up Your Scanner Installing the Battery PackCharging the Battery Pack Nickel-Metal Hydride Battery Disposal Installing the AntennaInstalling the Belt Clip Using Headphones or an External SpeakerListening Safely Setting the Squelch Basic OperationTurning On the Scanner Using the Menu Manually Selecting a ChannelScanning Programmed Channels Locking/Unlocking BanksLocking/Unlocking Channels Restoring All Locked Out ChannelsPriority Scanning Priority Plus ScanningListening to the Input Channel Using the Backlight Dimmer Light SettingDimmer Time Setting Controlling How Much Information AppearsTurning the Key Beep On/Off Locking the Enter keyLocking the Keypad Disabling the APCO25 CardTurning Battery Save On/Off Setting Squelch ModeMuting All Audio Trunk Scanning Options Searching for Active Talkgroups ID SearchScanning Only Stored Talkgroups ID Scan Monitoring Talkgroup ID’sHolding on a Single Talkgroup Locking Out TalkgroupsEdacs Blockout Unlocking All Talkgroups Edacs Patch TrackingSetting Chain Search Setting Data SkipSearching Holding on an Active FrequencySkipping Frequencies Storing Found FrequenciesSetting Subaudible Tones for Searching Automatically Storing FrequenciesSearching for Subaudible Tones Setting Delay for All Search Ranges Setting a Search RangeAttenuating All Search Ranges Searching for Trunk Systems Service Search Service Search SkipUsing Weather Search and Weather Alert Same Using Weather Alert SameSearching for a Weather Broadcast Dssccc Testing the Weather Alert Bank Configuration Programming Bank InformationAssigning Bank Names General Programming Deleting Frequencies from ChannelsTransferring Channel Information Entering Alpha InformationPage Programming Conventional Channels Select a Channel to ProgramEnter the Frequency Setting the Delay Setting the Subaudible Tone OptionAssigning a Text Tag Setting Beep Alert Setting the AttenuatorSetting the Modulation Mode Changing the Frequency StepSetting Priority Channels Programming Trunked Systems Setting Trunking Delay Using I-Call Motorola and Edacs onlyTurning I-Call On and Off for ID Search Setting Priority Talkgroups Motorola and Edacs only Multi-TrackTurning I-Call On for ID Scan Multi-Track Operational Details Using Control Channel Programming Programming Motorola SystemsProgramming Type 2/Digital 800 and 900 MHz Systems Programming Type2/Digital VHF and UHF SystemsProgramming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code Detect Programming Edacs Systems Programming Edacs ChannelsSetting Edacs Emergency Alert Setting Edacs Decimal ModeSetting Apco 25 Sound Quality Programming Apco SystemsPage Programming LTR Systems Programming Talkgroups Storing Known TalkgroupsStoring Found Talkgroups Press MENU/BACKDeleting Stored Talkgroup ID’s Adding a Text Tag to an ID ListSeeing Talkgroup Activity Using the Remote Interface PC Control ModeCloning Scanner Settings Clone Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Preset Fleet Maps AppendixPreset Map Block User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes NWR-SAME Event Code Reverse List 71.9 74.4 77.0 79.7 82.5 85.4 88.5 BC296D Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask One Year Limited Warranty Uniden America Corporation