Panasonic KX-T206E manual Conditions

Page 31

System Programming

Least Cost Routing (LCR) Programs (continued)

LCR Mode

Allows you to turn on or off the Least Cost Routing (LCR) mode. LCR, if enabled, selects the least expensive route to be used for a CO call. Input Format: #80 [A] [B]

[A]=1: CO1/ 2: CO2

[B]=0: DISABLE (default)/ 1: ENABLE

LCR Itemized Bill Code

Assigns whether to register the itemized bill code (extension number 21 through 26) to each CO line or not. This code is used for dividing a bill to a CO line.

Input Format: #86 [A] [B]

[A]=1: CO1/ 2: CO2

[B]=0: DISABLE (default)/ 1: ENABLE

LCR Carrier Code

Assigns each carrier's access code used for the LCR feature.

Input Format: #81 [A] [code] #

[A]=Route No.: 1 through 4

[code] =10 digits max.

(Default : all routes – 131)

BTL Access Code

Stores the BTL (British Telecom Line) access code. When this code is dialled, the BTL is always selected even if the LCR feature is enabled.

Input Format: #87 [code] #

• [code]=4 digits max. (default: 121)

LCR Modify Mode

Assigns whether to change the numbers after the carrier code to the TONE mode or not when “#01 Dial Type Selection” program is assigned as “Pulse”.

Input Format: #82 [A] [B]

[A]=Route No.: 1 through 4

[B]=0: PULSE/1: TONE (default)

LCR Route Selection Code

Assigns area codes (except the leading digit) which is selected by the LCR feature for each route. You can store a maximum of 40 codes for each route.

Input Format: #83 [A] [BB] [code] #

[A]= Route No.: 1 through 4

[BB]= Code No.: 00 through 39

[code]=6 digits max.

(Default: Not stored)

LCR Password Set

Assigns a password to register an authorization code. The password is not displayed on the display panel during setting.

Input Format: #84 [old password] [new password]

[Password]=4 digits max. (default: 1234)

LCR Authorization Code Set

Registers an authorization code applied to each CO line and each route. The authorization codes are not displayed on the display panel during setting.

Input Format: #85 [password] [A] [B] [code]

[password]=enter the password set by # 84 program

[A]=Route No.: 1 through 4

[B]=1: CO1/ 2: CO2

[code]=20 digits max.

(Default: both CO lines, all routes – not stored)

LCR Route Exceptional Code

Assigns dialling numbers that are excepted from LCR routing plans of the specified carrier. You can store a maximum of 20 codes for each route.

Input Format: #88 [A] [B] [code] #

[A]=Route No.: 1 through 4

[B]=Area code No.: 00 through 19

[code]= 6 digits max.

(Default: all routes – not stored)

LCR Leading Digit Entry

Registers Leading digits of an area code to judge whether to select a route for the LCR feature. When the first digit of the dialled number matches with the registered number, it is considered a long distance call and proceeds to the LCR procedure.

Input Format: #89 [code] #

• [code]=2 digits max. (default: 0)

Conditions

To clear the LCR route selection code, press #83 [A] [BB] #

To clear the LCR authorization code, press #85 [password] [A] [B] #

To clear the BTL access code, press #87#.

To clear the LCR route exceptional code, press #88 [A] [B] #

31

Image 31
Contents Electronic Modular Switching System For future reference System ComponentImportant Information For Your Safety Please Read the Following Text CarefullyOperation in Power Failure Precaution Table of Contents Characteristics SpecificationsGeneral Descriptions Wiring Precautions Before InstallationSafety Installation Instructions Installation PrecautionsInside View of the Main Unit UnpackingName and Location Overview of the Main UnitOpening Front Cover Wall MountingFrame Ground Connection System Connection Diagram CO Line Connection Extension Connection Wire Diameter of conductorParalleled Telephone Connection Doorphone KX-T30865 Connection Installation of Optional Card and UnitDoor Opener Connection Disa Card KX-T20691 Connection Installation Installation of Lightning ProtectorsOverview Outside Installation of an Earth RodStarting the System Power Failure TransferGeneral Programming Instructions Outgoing Permitted CO1 Assignment Day/Night System ProgrammingSystem Speed Dialling Number Set Dial Type SelectionCO1 Ringing Assignment Day/Night Outgoing Permitted CO2 Assignment Day/NightCO2 Ringing Assignment Day/Night Toll Restriction TRS Class Assignment Day/Night Doorphone Assignment Day/NightTRS Denied Code Class TRS Denied Code Class 2OGM Recording OGM Play CO1 Delayed Ringing AssignmentDelayed Ringing Count Selection CO2 Delayed Ringing AssignmentTRS Excepted Code System Data Clear Day/Night Switching ModeDoor Opener Assignment Day/Night Starting TimeOther Programs Disa Ringing Time Assignment CO Indicator AssignmentHookswitch Flash Time Range Assignment Door Opener Access TimeLeast Cost Routing LCR Programs LCR Sequence chartConditions Tone Tone / Ring ToneSec Ring Tone#00 System Speed Dialling Number Set Programming Tables#12 Fax Connection #13 CO 1 Delayed Ringing Assignment#14 CO 2 Delayed Ringing Assignment #15 Delayed Ringing Count Selection#83 LCR Route Selection Code #70 Day/Night Switching Mode#61 Door Opener Assignment #71 Day/Night Starting Time#88 LCR Route Exceptional Code Page Templet Panasonic Business Systems U.K