Panasonic KX-T206E manual Disa Ringing Time Assignment, Toll Restriction Code Check

Page 29

System Programming

Other Programs (continued)

DISA Ringing Time Assignment

Sets the time to forward a call sent by the DISA feature to other extensions. If the call is not answered by the designated extension within the programmed time, the call is forwarded to extensions which are not assigned as “DIS- ABLE” in the #04/#74 CO1 Ringing Assignment (Day/Night) and #05/#75 CO2 Ringing Assign- ment (Day/Night). If “DISABLE” is selected in this program, the telephone at the designated extension rings for 60 seconds and the call is not forwarded.

Input Format: #60 [A]

[A]=0: DISABLE / 1: 10 SEC/

2:20 SEC (default)/ 3: 35 SEC

Toll Restriction Code Check

Assigns whether “ ” or “#” is to be checked or not when a user dials them in the Toll Restriction code.

Input Format: #62 [A]

[A]=0: DISABLE/ 1: ENABLE (default)

CO Indicator Assignment

Assigns whether an incoming CO call indicates or not on the CO button. Also it allows an extension user to answer the call by pressing the CO button when “DISABLE” is selected in the #04/#74 “CO1 Ringing Assignment” or the #05/ #75 “CO2 Ringing Assignment” program. Input Format: #63 [A]

[A]=0: DISABLE (The indicator lights red and a user cannot answer the call.)

1:ENABLE (The indicator is flashing and a user can answer the call.) (default)

Hookswitch Flash Time Range Assignment

Sets the hookswitch flash time range. Input Format: #65 [A]

[A]=1: 80–1000ms / 2: 80–150ms

3:50–150ms (default)

Door Opener Access Time

Assigns the length of the Door Opener time. The door is unlocked for the assigned time. Input Format: #67 [A]

[A]= 1: 1 sec/ 2: 2 sec/ 3: 3 sec/ 4: 4 sec/

5:5 sec (default) / 6: 6 sec/ 7: 7 sec /

8:8 sec

Note

You cannot check the assignments of the programs, #60, #62, #63, #65 and #67 by setting the MEMORY switch to “PROGRAM”, and entering “#” and the program address.

29

Image 29
Contents Electronic Modular Switching System For future reference System ComponentImportant Information For Your Safety Please Read the Following Text CarefullyOperation in Power Failure Precaution Table of Contents General Descriptions SpecificationsCharacteristics Safety Installation Instructions Before InstallationInstallation Precautions Wiring PrecautionsName and Location UnpackingOverview of the Main Unit Inside View of the Main UnitFrame Ground Connection Wall MountingOpening Front Cover System Connection Diagram CO Line Connection Extension Connection Wire Diameter of conductorParalleled Telephone Connection Door Opener Connection Installation of Optional Card and UnitDoorphone KX-T30865 Connection Disa Card KX-T20691 Connection Overview Installation of Lightning ProtectorsInstallation Outside Installation of an Earth RodStarting the System Power Failure TransferGeneral Programming Instructions System Speed Dialling Number Set System ProgrammingDial Type Selection Outgoing Permitted CO1 Assignment Day/NightCO2 Ringing Assignment Day/Night Outgoing Permitted CO2 Assignment Day/NightCO1 Ringing Assignment Day/Night Toll Restriction TRS Class Assignment Day/Night Doorphone Assignment Day/NightOGM Recording TRS Denied Code Class 2TRS Denied Code Class OGM Play CO1 Delayed Ringing AssignmentTRS Excepted Code CO2 Delayed Ringing AssignmentDelayed Ringing Count Selection Door Opener Assignment Day/Night Switching ModeDay/Night Starting Time System Data ClearOther Programs Hookswitch Flash Time Range Assignment CO Indicator AssignmentDoor Opener Access Time Disa Ringing Time AssignmentLeast Cost Routing LCR Programs LCR Sequence chartConditions Tone Tone / Ring ToneSec Ring Tone#00 System Speed Dialling Number Set Programming Tables#14 CO 2 Delayed Ringing Assignment #13 CO 1 Delayed Ringing Assignment#15 Delayed Ringing Count Selection #12 Fax Connection#61 Door Opener Assignment #70 Day/Night Switching Mode#71 Day/Night Starting Time #83 LCR Route Selection Code#88 LCR Route Exceptional Code Page Templet Panasonic Business Systems U.K