Panasonic KX-T206E manual OGM Play, CO1 Delayed Ringing Assignment

Page 25

System Programming

OGM Play

Description

Confirms the outgoing message recorded in the OGM Recording program.

Condition

If you perform programming with a PT, the message “PLAYBACK” will be displayed on its panel.

Input Format

1 1

Fax Connection

Description

Allows the system to detect the CNG tone from a facsimile. If it is set to “ENABLE”, extension 26 will receive fax transmission data.

Condition

The optional DISA/FAX Detect card (KX-T20691) should be installed.

The “#24 Call Incoming Mode Selection” program should be assigned as “DISA”.

Extension 26 should be assigned as “DISABLE” in the “#04/#74 CO1 Ringing Assignment (Day/Night)”, “#05/#75 CO2 Ringing Assignment (Day/Night)” and “#06/#76 Doorphone Assignment (Day/Night)” programs.

Input Format

Explanation

1 2 [A]

• [A]= 0: DISABLE (not detect)/ 1: ENABLE (detect)

Default

0: DISABLE

CO1 Delayed Ringing Assignment

Description

Assigns delayed ringing to extensions when a call from CO line 1 is received.

Condition

The number of delayed rings is assigned by the “#15 Delayed Ringing Count Selection” program.

This feature is not available for the calls sent by the DISA feature.

Input Format

Explanation

1 3 [A] [B]

[A]= 1 through 6 (corresponding to extension no. 21 through 26)

[B]= 0: DISABLE (not delayed)/ 1: ENABLE (delayed)

Default All extensions– 0: DISABLE

25

Image 25
Contents Electronic Modular Switching System For future reference System ComponentImportant Information For Your Safety Please Read the Following Text CarefullyOperation in Power Failure Precaution Table of Contents Characteristics SpecificationsGeneral Descriptions Safety Installation Instructions Before InstallationInstallation Precautions Wiring PrecautionsName and Location UnpackingOverview of the Main Unit Inside View of the Main UnitOpening Front Cover Wall MountingFrame Ground Connection System Connection Diagram CO Line Connection Extension Connection Wire Diameter of conductorParalleled Telephone Connection Doorphone KX-T30865 Connection Installation of Optional Card and UnitDoor Opener Connection Disa Card KX-T20691 Connection Installation Installation of Lightning ProtectorsOverview Outside Installation of an Earth RodStarting the System Power Failure TransferGeneral Programming Instructions System Speed Dialling Number Set System ProgrammingDial Type Selection Outgoing Permitted CO1 Assignment Day/NightCO1 Ringing Assignment Day/Night Outgoing Permitted CO2 Assignment Day/NightCO2 Ringing Assignment Day/Night Toll Restriction TRS Class Assignment Day/Night Doorphone Assignment Day/NightTRS Denied Code Class TRS Denied Code Class 2OGM Recording OGM Play CO1 Delayed Ringing AssignmentDelayed Ringing Count Selection CO2 Delayed Ringing AssignmentTRS Excepted Code Door Opener Assignment Day/Night Switching ModeDay/Night Starting Time System Data ClearOther Programs Hookswitch Flash Time Range Assignment CO Indicator AssignmentDoor Opener Access Time Disa Ringing Time AssignmentLeast Cost Routing LCR Programs LCR Sequence chartConditions Tone Tone / Ring ToneSec Ring Tone#00 System Speed Dialling Number Set Programming Tables#14 CO 2 Delayed Ringing Assignment #13 CO 1 Delayed Ringing Assignment#15 Delayed Ringing Count Selection #12 Fax Connection#61 Door Opener Assignment #70 Day/Night Switching Mode#71 Day/Night Starting Time #83 LCR Route Selection Code#88 LCR Route Exceptional Code Page Templet Panasonic Business Systems U.K