Chapter 5 Parameter Definitions

5.3Signaling Gateway Timers

5.3.1Signaling Gateway-Specific Timers

Table 4 shows the Signaling Gateway specific timers. Timers for specific protocols are given in subsequent tables in this section.

Table 4. Signaling Gateway Specific Timers

T0

Range

Default

Description

(seconds)

(seconds)

 

 

 

 

 

 

 

 

 

Wait for board response guard timer. This timer starts when internal

 

 

 

messages are sent to a signaling board and stopped when an

5

5 to 20

7

acknowledgement is received. On timer expiry, it reports an error. If the

 

 

 

internal message sent to a board related to setting up a speech path for a

 

 

 

call, then the call is released using internal token 135.

 

 

 

 

 

 

 

MML wait for maintenance confirmation timer. The timer is started when a

7

2 to 10

3

MML maintenance request is performed. It is stopped when a confirmation

from the remote site to the maintenance request is received. On timer

 

 

 

expiry, a confirmation to the request is internally generated allowing

 

 

 

further MML commands to be entered.

 

 

 

 

5.3.2MTP3-Specific Timers MTP3 ITU timers are given in Table 5.

Table 5. MTP3 ITU Timers

TO

Range

Default

Description

(milliseconds)

(milliseconds)

 

 

 

 

 

 

1

500 to 1200

1000

Delay to avoid message mis-sequencing on changeover

 

 

 

 

2

700 to 2000

1500

Waiting for changeover acknowledgement

 

 

 

 

3

500 to 1200

1000

Time controlled diversion-delay to avoid mis-sequencing on

changeback

 

 

 

 

 

 

 

4

500 to 1200

1000

Waiting for changeback acknowledgement (first attempt)

 

 

 

 

5

500 to 1200

1000

Waiting for changeback acknowledgement (second attempt)

 

 

 

 

6

500 to 1200

1000

Delay to avoid message mis-sequencing on controlled rerouting

 

 

 

 

10

30 to 60 sec.

45 sec.

Waiting to repeat signaling route set test message

 

 

 

 

12

800 to 1500

1200

Waiting for uninhibit acknowledgement

 

 

 

 

13

800 to 1500

1200

Waiting for force uninhibit

 

 

 

 

14

2000 to 3000

3000

Waiting to start signaling route set congestion test

 

 

 

 

17

800 to 1500

1000

Delay to avoid oscillation of initial alignment failure and link

restart

 

 

 

 

 

 

 

22

180 to 360 sec.

270 sec.

Local inhibit test timer

 

 

 

 

23

180 to 360 sec.

270 sec.

Remote inhibit test timer

 

 

 

 

24

N/A

N/A

Reserved

 

 

 

 

MTP3 ANSI timers are given in Table 6.

Table 6. MTP3 ANSI Timers

 

Range

Default

 

TO

(milli-

Description

(milliseconds)

 

seconds)

 

 

 

 

 

 

 

 

1

500 to 1200

1000

Delay to avoid message mis-sequencing on changeover

 

 

 

 

2

700 to 2000

1500

Waiting for changeover acknowledgement

 

 

 

 

3

500 to 1200

1000

Time controlled diversion-delay to avoid mis-sequencing on

changeback

 

 

 

 

 

 

 

4

500 to 1200

1000

Waiting for changeback acknowledgement (first attempt)

 

 

 

 

5

500 to 1200

1000

Waiting for changeback acknowledgement (second attempt)

 

 

 

 

38

Page 38
Image 38
Dialogic SS7G2X manual Signaling Gateway Timers Signaling Gateway-Specific Timers, Signaling Gateway Specific Timers