Chapter 9 Remote Data Centre Operation

9.3.3SIGTRAN Link Traffic Measurements

Measurements collected on a per SIGTRAN link basis can be transferred periodically to the RDC. These measurements can optionally be reset at the expiry of each interval.

9.3.4Ethernet Port Traffic Measurements

Measurements collected on performance data associated with Ethernet ports can be transferred periodically to the RDC. These measurements can optionally be reset at the expiry of each interval.

9.3.5System Measurements

Measurements collected on system performance data can be transferred periodically to the RDC. These measurements can optionally be reset at the expiry of each interval.

9.4RDC File Formats

This section specifies the file formats for records that are sent from the Signaling Gateway to a Remote Data Centre (RDC). As shown in the examples, the records are provided in CSV (Comma Separated Variable) text file format.

9.4.1Alarm Record File Format

10,11,1,0,3,A,2001-01-01,00:00:35,,,Linkset fail 11,9,1,0,2,A, 2001-01-01,00:00:35,,,C7 link fail

2,44,1,3,2,C, 2001-01-01,00:00:28, 2001-01-01,00:00:36,CR send fail 11,9,1,0,2,C, 2001-01-01,00:00:35, 2001-01-01,00:00:36,C7 link fail 10,11,1,0,3,C, 2001-01-01,00:00:35, 2001-01-01,00:00:36,Linkset fail

Field

Title

Example

Range

Description

 

 

 

 

 

1

ALP

10

1 to 9999

Sequence reference number

of an entry in the alarm log

 

 

 

 

 

 

 

 

 

2

CODE

11

1 to 999

Fault code of a system alarm

 

 

 

 

 

3

ID

1

0 to 9999

Identifier for alarm (usage

depends on the alarm code)

 

 

 

 

 

 

 

 

 

4

DIAG

0

0 to 9999

Diagnostic of the alarm (usage

depends on the alarm code)

 

 

 

 

 

 

 

 

 

5

CLA

3

0 to 3

Alarm class number

 

 

 

 

 

6

ACTIVE

C

A or C

Indication whether the alarm

is Active or Cleared

 

 

 

 

 

 

 

 

 

7

DATE OCCURRED

1970-01-01

yyyy-mm-dd

Date the alarm occurred

 

 

 

 

 

8

TIME OCCURED

00:00:35

hh:mm:ss

Time the alarm occurred

 

 

 

 

 

9

DATE CLEARED

1970-01-01

yyyy-mm-dd

Date the alarm cleared

 

 

 

 

 

10

TIME CLEARED

00:00:36

hh:mm:ss

Time the alarm cleared

 

 

 

 

 

11

TITLE

Linkset fail

Up to 12 text

Title of the alarm

characters

 

 

 

 

 

 

 

 

 