Chapter 6 Command Definitions

6.10.3MSPCP – Measurements PCM Print

Synopsis

This command prints traffic measurements for PCMs. The measurements are cumulative between system startup and the next time the measurements are reset.

The fields have the following meanings:

PCM - PCM on a board

FMSLIP - Frame Slip count

OUTSYN - Out-sync transitions

ERRSEC - Errored Seconds count

SEVSEC - Severely Errored seconds count

PERIOD - Time since measurements on the route were last reset. Specified in hours, minutes and seconds

Syntax

MSC7P:[C7LINK=,][RESET=,];

Prerequisites

If specified, the PCM must be initiated and on an unblocked board.

Attributes

None

Examples

MSPCP:PCM=5-1;

MSPCP;

Output Format

PCM Traffic Measurements

 

 

PCM

FMSLIP

OUTSYN

ERRSEC

SEVSEC

PERIOD

3-3

57

60

23

1

23:00:00

3-4

12

35

33

4

01:00:00

4-4

53

55

4

0

01:00:00

EXECUTED

94

Page 94
Image 94