Dialogic SS7G2X manual Allip Alarm List Print

Models: SS7G2X

1 170
Download 170 pages 7.13 Kb
Page 44
Image 44

Chapter 6 Command Definitions

6.4.4ALLIP – Alarm List Print

Synopsis

This command gives a printout of all ACTIVE fault codes stored in the system’s alarm log.

Each fault code (CODE) is associated with an alarm class (CLA) which may be Minor, Major or Critical. The alarm class in turn governs which alarm LED, relay or SNMP alarm is activated when the condition exists.

The command provides an indication of the time that the alarm occurred (OCCURRED), the alarm class (CLA indicating either a System, PCM or signaling failure) as well as an alarm code specific identifier (ID) and diagnostic field (DIAG).

See Chapter 8, “Alarm Fault Code Listing” for the definitions of the alarm code specific parameters.

Note: The meaning of the ID field depends on the alarm code and is described in Chapter 8, “Alarm Fault Code Listing”.

Syntax

ALLIP;

Prerequisites

None

Attributes

None

Examples

ALLIP;

Output Format

SYSTEMIDENT1 Alarm

List (active alarms) 1996-12-01

00:00:54

ALP

CODE

ID

DIAG

CLA

OCCURRED

CLEARED

TITLE

107

1

103

0

1

A

2001-10-30

10:54:48

PCM loss

74

1

104

0

2

A

2001-10-30

10:54:27

PCM loss

EXECUTED