Chapter 6 Command Definitions

6.14.1STALP – Status Alarm Print

Synopsis

This command requests an alarm status report summary. The interpretation of the ID field in the listing is dependent on the alarm type (see Chapter 8, “Alarm Fault Code Listing”).

The fields have the following meanings:

SYS - The number of system alarms PCM - The number of PCM alarms SIG - The number of signaling alarms CLA1 - The number of minor alarms CLA2 - The number of major alarms CLA3 - The number of critical alarms

Syntax

STALP;

Prerequisites

None

Attributes

None

Examples

STALP;

Output Format

Alarm Status

SYS PCM SIG CLA1 CLA2 CLA3

1 0 1 2 0 0 EXECUTED

124

Page 124
Image 124