Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4
Table 2. Parameter Definitions (Continued)
Name | Description |
| Range | Notes | |
|
|
|
|
| |
| Specifies the type of restart operation, |
|
|
| |
| which can be one of the following: |
|
|
| |
| • NORMAL - The system undergoes a full |
|
|
| |
| system restart, resetting the hardware, |
|
|
| |
| operating system and SIU software. |
|
|
| |
| This is the default behavior. NORMAL |
|
|
| |
| resets should be used for software |
|
|
| |
| upgrade or for maintenance events. |
|
|
| |
| • SOFT - The system restarts the |
|
|
| |
| application software. Prior to a soft | One of: |
| ||
| restart, the Signaling boards are reset. |
| |||
| • | NORMAL |
| ||
RESTART | SOFT resets may be used for a more |
| |||
rapid system restart after updating the | • | SOFT |
| ||
|
| ||||
| system configuration or licenses. | • | HALT |
| |
| However, if a new software distribution |
| |||
|
|
|
| ||
| is to be installed, the system performs |
|
|
| |
| a NORMAL restart. |
|
|
| |
| • HALT - The system shuts down without |
|
|
| |
| a subsequent restart. |
|
|
| |
| Caution: Once the system has been |
|
|
| |
| halted, the only way to restart the unit |
|
|
| |
| is by physically pressing the Power |
|
|
| |
| switch on the front panel of the |
|
|
| |
| chassis. |
|
|
| |
|
|
|
|
| |
| Routing Key Index |
|
|
| |
RKI | An identifier for either a complete routing | 1 to 512 |
| ||
| key or part of a routing key. |
|
|
| |
|
|
|
|
| |
RKTAB | Routing Key Table | 1 to 8 |
| ||
A table of particular routing keys. |
| ||||
|
|
|
| ||
|
|
|
| ||
|
| One of: |
| ||
RTPRI | Destination route priority | • | NONE | Default = NONE | |
|
| • | MTP |
| |
|
|
|
|
| |
| A timeslot within a PCM interface on a board |
|
|
| |
| used for monitoring information received by |
|
|
| |
| the monitored object. The format is: | xx – 1 to 3 |
| ||
|
| ||||
RTS | y – 1 to 4 |
| |||
where: |
| ||||
| zz – 1 to 31 |
| |||
| • xx = board position (BPOS) |
| |||
|
|
|
| ||
| • y = PCM within a board |
|
|
| |
| • zz = timeslot |
|
|
| |
|
|
|
| ||
SBITS | Number of stop bits on V.24 port | 1 to 2 | Default = 1 | ||
|
|
|
|
| |
| Secure operation. When active offers a |
|
|
| |
| higher level of security. The use of the |
|
|
| |
SECURE | parameter is command specific. See the | Y or N | Default = N | ||
| CNSYS and SNSLI command descriptions |
|
|
| |
| for more information. |
|
|
| |
|
|
|
| ||
SEQ | Sequence number | 1 to 32 |
| ||
|
|
|
|
| |
SG | Reserved |
|
|
| |
|
|
|
|
| |
SI | Reserved |
|
|
| |
|
|
|
|
| |
SIGTYPE | Type of software loaded onto signaling | SS7 |
|
| |
board |
|
| |||
|
|
|
| ||
|
|
|
|
| |
SLC | Signaling link code uniquely identifying a | 0 to 15 |
| ||
signaling link within a link set |
| ||||
|
|
|
| ||
|
|
|
|
| |
SNMP | Whether SNMP should be active on the | Y or N | Default = N | ||
system | |||||
|
|
|
| ||
|
|
|
|
| |
SNRT | Reserved |
|
|
| |
|
|
|
| ||
|
| One of: |
| ||
SNTYPE | The type of operation of the SIGTRAN link | • | SGM3UA |
| |
|
| • | M2PA |
| |
|
|
|
| ||
SNLINK | Logical reference for a SIGTRAN link | 1 to 200 |
| ||
|
|
|
|
|
35