Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4

Table 2. Parameter Definitions (Continued)

Name

Description

 

Range

Notes

 

 

 

 

 

 

Specifies the type of restart operation,

 

 

 

 

which can be one of the following:

 

 

 

 

• NORMAL - The system undergoes a full

 

 

 

 

system restart, resetting the hardware,

 

 

 

 

operating system and SIU software.

 

 

 

 

This is the default behavior. NORMAL

 

 

 

 

resets should be used for software

 

 

 

 

upgrade or for maintenance events.

 

 

 

 

• SOFT - The system restarts the

 

 

 

 

application software. Prior to a soft

One of:

 

 

restart, the Signaling boards are reset.

 

 

NORMAL

 

RESTART

SOFT resets may be used for a more

 

rapid system restart after updating the

SOFT

 

 

 

 

system configuration or licenses.

HALT

 

 

However, if a new software distribution

 

 

 

 

 

 

is to be installed, the system performs

 

 

 

 

a NORMAL restart.

 

 

 

 

• HALT - The system shuts down without

 

 

 

 

a subsequent restart.

 

 

 

 

Caution: Once the system has been

 

 

 

 

halted, the only way to restart the unit

 

 

 

 

is by physically pressing the Power

 

 

 

 

switch on the front panel of the

 

 

 

 

chassis.

 

 

 

 

 

 

 

 

 

Routing Key Index

 

 

 

RKI

An identifier for either a complete routing

1 to 512

 

 

key or part of a routing key.

 

 

 

 

 

 

 

 

RKTAB

Routing Key Table

1 to 8

 

A table of particular routing keys.

 

 

 

 

 

 

 

 

 

 

 

One of:

 

RTPRI

Destination route priority

NONE

Default = NONE

 

 

MTP

 

 

 

 

 

 

 

A timeslot within a PCM interface on a board

 

 

 

 

used for monitoring information received by

 

 

 

 

the monitored object. The format is:

xx – 1 to 3

 

 

xx-y-zz

 

RTS

y – 1 to 4

 

where:

 

 

zz – 1 to 31

 

 

• xx = board position (BPOS)

 

 

 

 

 

 

• y = PCM within a board

 

 

 

 

• zz = timeslot

 

 

 

 

 

 

 

SBITS

Number of stop bits on V.24 port

1 to 2

Default = 1

 

 

 

 

 

 

Secure operation. When active offers a

 

 

 

 

higher level of security. The use of the

 

 

 

SECURE

parameter is command specific. See the

Y or N

Default = N

 

CNSYS and SNSLI command descriptions

 

 

 

 

for more information.

 

 

 

 

 

 

 

SEQ

Sequence number

1 to 32

 

 

 

 

 

 

SG

Reserved

 

 

 

 

 

 

 

 

SI

Reserved

 

 

 

 

 

 

 

 

SIGTYPE

Type of software loaded onto signaling

SS7

 

 

board

 

 

 

 

 

 

 

 

 

 

 

SLC

Signaling link code uniquely identifying a

0 to 15

 

signaling link within a link set

 

 

 

 

 

 

 

 

 

 

SNMP

Whether SNMP should be active on the

Y or N

Default = N

system

 

 

 

 

 

 

 

 

 

SNRT

Reserved

 

 

 

 

 

 

 

 

 

One of:

 

SNTYPE

The type of operation of the SIGTRAN link

SGM3UA

 

 

 

M2PA

 

 

 

 

 

SNLINK

Logical reference for a SIGTRAN link

1 to 200

 

 

 

 

 

 

35

Page 35
Image 35
Dialogic SS7G2X Normal Restart, Soft, Halt, Rki, Rktab, Rtpri, Mtp, Rts, Sbits, Secure, Seq, Sigtype, Slc, Snmp, Snrt