Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4

9.4.2Ethernet Port Measurements File Format

2005-11-16,14:40:01,1,265,2016,0,0,0,0,0,0,119,1136,0,0,0,0,0,0,2077

2005-11-16,14:40:01,4,4664602,3448084,0,0,0,0,0,0,1183455,1809415,0,0,0,0,0,0,2077

2005-11-16,14:45:01,1,301,2368,0,0,0,0,0,0,145,1379,0,0,0,0,0,0,2377

2005-11-16,14:45:01,4,10220775,7212808,0,0,0,0,0,0,1270164,3077831,0,0,0,0,0,0,2377

Field

Field

Example

Range

Description

 

 

 

 

 

1

Date

2005-11-16

yyyy-mm-dd

Date when measurements collected

 

 

 

 

 

2

Time

14:40:01

hh:mm:ss

Time when measurements collected

 

 

 

 

 

3

ETH

1

1 to 4

Ethernet port number

 

 

 

 

 

4

RXKBYTE

10220775

0 to 4294967295

Number of kilobytes of data received

(in kilobytes)

 

 

 

 

 

 

 

 

 

5

RXPKT

7212808

0 to 4294967295

Number of packets of data received

 

 

 

 

 

6

RXERR

0

0 to 4294967295

Number of receive errors detected

 

 

 

 

 

7

RXDROP

0

0 to 4294967295

Number of received packets dropped by the

device driver

 

 

 

 

 

 

 

 

 

8

RXFIFO

0

0 to 4294967295

The number of FIFO buffer errors received

 

 

 

 

 

9

RXFRAME

0

0 to 4294967295

The number of packet framing errors

received

 

 

 

 

 

 

 

 

 

10

RXCOMP

0

0 to 4294967295

The number of compressed packets received

 

 

 

 

 

11

RXMULT

0

0 to 4294967295

The number of multicast frames received

 

 

 

 

 

12

TXKBYTE

1270164

0 to 4294967295

Number of kilobytes of data transmitted

(in kilobytes)

 

 

 

 

 

 

 

 

 

13

TXPKT

3077831

0 to 4294967295

Number of packets of data transmitted

 

 

 

 

 

9.4.3PCM Measurements File Format

2001-12-31,13:07:25,600,1-1,5,50,20,500

2001-01-01,01:01:00,86400,1-2,90,1000,1000,1000

2001-11-22,19:07:38,3600,2-1,1,0,0,0

Field

Title

Example

Range

Description

 

 

 

 

 

1

Date

2001-12-31

yyyy-mm-dd

Date when measurements

collected

 

 

 

 

 

 

 

 

 

2

Time

13:07:25

hh:mm:ss

Time when measurements

collected

 

 

 

 

 

 

 

 

 

3

Period

600

0:4294967295

Duration of measurement

period in seconds

 

 

 

 

 

 

 

 

 

4

PCM

3-1

x: 1 to 3

PCM: x-y

y: 1 to 4

board id – port id.

 

 

 

 

 

 

 

 

5

Frame Slip counter

50

0 to 4294967295

Number of frame slips

occurred.

 

 

 

 

 

 

 

 

 

6

Out of synchronism

1000

0 to 4294967295

Number of out-sync

transitions

transitions.

 

 

 

 

 

 

 

 

7

Errored Seconds

20

0 to 4294967295

Number of Errored Seconds

counter

occurred.

 

 

 

 

 

 

 

 

8

Severely Errored

500

0 to 4294967295

Number of Severely Errored

Seconds counter

Seconds.

 

 

 

 

 

 

 

 

153

Page 153
Image 153
Dialogic SS7G2X manual Ethernet Port Measurements File Format, PCM Measurements File Format