Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.5.21CNTOS – Configuration Timeout Value Set

Synopsis

This command is used to change the value of a timer for a particular signaling system.

The user should specify the timer type (TTYPE), the timer itself (TO) and time that it should be set to, expressed in either seconds (TSEC) or milliseconds (TMSEC).

Note: Some signaling system timer values are not changeable.

See the CNTOP command to verify timer values. See Section 5.3, “Signaling Gateway Timers” on page 38 for the definition of signaling system specific timers.

Syntax

CNTOS:TTYPE=,TO=,{TSEC=TMSEC=};

Prerequisites

None

Attributes

CONFIG

Examples

CNTOS:TTYPE=MTP3,TO=7,TSEC=30;

6.5.22CNTOP – Configuration Timeout Value Print

Synopsis

This command is used to print the value of either a single timer or all the timers for a particular protocol module. (Refer to CNTOS command to set timer values.)

Syntax

CNTOP:TTYPE=,[TO=,];

Prerequisites

None

Attributes

None

Examples

CNTOP:TTYPE=MTP3;

Output Format

Timeout Values:

TTYPE

TO

TSEC TMSEC

MTP3

1

60

MTP3

2

360

MTP3

3

120

MTP3

4

360

MTP3

5

5

MTP3

6

5

MTP3

7

3

MTP3

10

60

EXECUTED

61

Page 61
Image 61
Dialogic SS7G2X manual Cntos Configuration Timeout Value Set, Cntop Configuration Timeout Value Print