Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4

9.4.5SIGTRAN Link Measurements File Format

2001-12-31,13:07:25,600,2,886,888,5,0,0

2001-01-01,01:01:00,86400,5,5000,6000,1000,1000,65

2001-11-22,19:07:38,3600,1,0,0,0,0,0

Field

Title

Example

Range

Description

 

 

 

 

 

1

Date

2001-12-31

yyyy-mm-dd

Date when measurements

collected

 

 

 

 

 

 

 

 

 

2

Time

13:07:25

hh:mm:ss

Time when measurements

collected

 

 

 

 

 

 

 

 

 

3

Period

600

0 to 4294967295

Duration of measurement

period in seconds

 

 

 

 

 

 

 

 

 

4

SIGTRAN Link

2

0 to 32

SIGTRAN Link Number.

 

 

 

 

 

5

Chunks Received

886

0 to 4294967295

Number of chunks received

in the link.

 

 

 

 

 

 

 

 

 

6

Chunks Transmitted

888

0 to 4294967295

Number of chunks

transmitted in the link.

 

 

 

 

 

 

 

 

 

7

Chunks

5

0 to 4294967295

Number of chunks

Retransmitted

retransmitted in the link.

 

 

 

 

 

 

 

 

8

Number of times out

0

0 to 4294967295

Duration in abort and

of service.

shutdown states.

 

 

 

 

 

 

 

 

9

Out of service

0

0 to 4294967295

Duration of the link out of

duration.

service since last reset.

 

 

 

 

 

 

 

 

9.4.6System Measurements File Format

2005-11-16,14:40:01,0,231,155,8462

2005-11-16,14:45:01,0,368,159,8762

2005-11-16,14:50:01,0,380,164,9062

Field

Field

Example

Range

Description

 

 

 

 

 

1

Date

2005-11-16

yyyy-mm-dd

Date when measurements collected

 

 

 

 

 

2

Time

14:40:01

hh:mm:ss

Time when measurements collected

 

 

 

 

 

3

NOVLD

0

0 to 65535

The number of periods of congestion

(overload) during the measurement period

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum load average measurement taken

4

MAXLOAD

380 (3.8%)

0 to 10000

over 1 minute (based on the UNIX load

 

 

 

 

average) multiplied by 100

 

 

 

 

 

 

 

 

 

The average load on the system (based on

5

LOADAVG

164 (1.64%)

0 to 10000

the UNIX load average) measurement taken

over the measurement period multiplied by

 

 

 

 

 

 

 

 

100

 

 

 

 

 

6

PERIOD

9062

0 to 4294967295

Duration of measurement period in seconds

 

 

 

 

 

9.5RDC Configuration and Usage

This section provides a guide to the configuration of the Signaling Gateway for RDC operation, the text demonstrates by example, the man machine language (MML) commands and parameters required to invoke those services that transfer data to and from the RDC.

9.5.1RDC Initialization

Initialize the RDC using the CNRDI command:

CNRDI:RDC=1,IPADDR=123.123.123.12,USER=ANONYMOUS,PASSWORD=ANONYMOUS, LABEL=MYWORKSTN;

Unblock the RDC using the MNBLE command:

MNBLE:RDC=1;

Check the status of the RDC with the STRDP command:

155

Page 155
Image 155
Dialogic SS7G2X manual Sigtran Link Measurements File Format, System Measurements File Format, RDC Configuration and Usage