Chapter 6 Command Definitions

6.5.23CNTSP – Configuration Timeslot Print

Synopsis

This command is used to print the configuration of all timeslots on a PCM.

A timeslot on a PCM can be allocated to signaling, voice, cross connect, monitoring or it can be unallocated. Data is printed for a timeslot when it is acting as an outgoing timeslot.

A timeslot can act as an outgoing timeslot for the following types:

SIG - Carries signaling information. It forms a duplex connection.

OTS - Acts as an outgoing timeslot for a cross connection. It may form a duplex connection.

STS - The outgoing timeslot monitoring the send direction of an object.

RTS - The outgoing timeslot monitoring the receive direction of an object.

Note: An object is currently only a signaling link.

For signaling, the STS monitors information sent from the EQU of the signaling link and the RTS monitors information received by the signaling link.

Syntax

CNTSP:PCM=;

Prerequisites

None

Attributes

None.

Examples

CNTSP:PCM=3-3;

Output Format

PCM Timeslot

Configuration

TS

TYPE

C7LINK ITS

3-3-22

SIG

6

3-3-24

OTS

4-4-4

3-3-25

RTS

7

3-3-25 STS

8

EXECUTED

 

 

62

Page 62
Image 62
Dialogic SS7G2X manual Cntsp Configuration Timeslot Print