Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.6.1C7LSI – CCS SS7 Link Set Initiate

Synopsis

This command is used to initiate the SS7 link set (LS) between the point code of the unit, the Originating Point Code (OPC), and an adjacent point code, the Destination Point Code (DPC). The user should specify the maximum number of links in the link set (LSSIZE), the SS7 Signaling mode (SS7MD), which identifies the point code size and mode of operation, and the Network Context (NC) the link set exists within.

See Section 7.2, “Signaling Configuration” on page 136 for a more detailed description of the SS7 Signaling configuration.

This command is used to initiate the SS7 link set. Note that the DPC (Destination Point Code) is the adjacent Point Code for the link set.

Syntax

C7LSI:LS=,OPC=,DPC=,LSSIZE=,NI=,SS7MD=,NC=,;

Prerequisites

The SS7 link set has not already been initiated.

The SS7MD associated with a NC cannot be different to an SS7MD associated with the same NC anywhere else in the system.

The NC/DPC combination must be different for all link sets.

If SS7MD indicates 14-bit Point Code, OPC and DPC must be less than or equal to 16383. If SS7MD indicates 16-bit Point Code, OPC and DPC must be less than or equal to 65535. Only one OPC can exist within a network context.

Attributes

CONFIG

Examples

C7LSI:LS=1,NC=1,OPC=1,DPC=2,LSSIZE=2,SS7MD=ITU14,NI=0;

67

Page 67
Image 67
Dialogic SS7G2X manual 1 C7LSI CCS SS7 Link Set Initiate