Chapter 6 Command Definitions

6.9.2MNBLE – Maintenance Blocking End

Synopsis

This command ends the blocked condition of boards, signaling links, remote data centres, SIGTRAN links and SIGTRAN Application Servers and brings them into service. The command restores configuration data to the lower levels of the Signaling Gateway and brings the timeslots into service. Possible grouping are:

SS7 signaling links

Boards

Remote Data Centres (RDCs)

SIGTRAN signaling links

SIGTRAN Application Servers

Note: If an RDC has previously been blocked but a file transfer was already in progress, subsequent MNBLE commands which use that RDC fail with “NO SYSTEM RESOURCES” until the file transfer is complete.

Syntax

MNBLE:C7LINK=…;

MNBLE:BPOS=…;

MNBLE:RDC=…;

MNBLE:SNLINK=…;

MNBLE:AS=…;

Prerequisites

The item being unblocked has been initiated and is currently blocked.

When unblocking an SS7 link with a signaling processor (EQU), both the board containing the signaling processor and the board containing the signaling timeslot must already be unblocked.

An SS7 link with a signaling processor (EQU) cannot be unblocked until all the boards processing the SS7 signaling are blocked and then unblocked.

An SS7 link cannot be unblocked if it is on a C7 route that has more than one link set and those link sets have either different OPCs, SS7MDs, NCs or NIs.

An AS cannot be unblocked unless it has a SNLINK attached.

An M3UA SNLINK must have a default NC or a mapping of an NA into an NC.

An M3UA SNLINK must have a mapping of an NA into an NC or a default NC matching the AS NC the SNLINK is attached to.

All the underlying SNLINKs of an AS must have a mapping of an NA into an NC or a default NC matching the AS NC.

A C7LINK cannot be unblocked if an associated SNLINK is blocked.

A network facing M2PA C7LINK can only be unblocked if the Signaling Gateway is licensed for M2PA operation.

Note: M2PA can be used for DUAL operation without a license.

Attributes

CONFIG

Examples

MNBLE:C7LINK=4;

Output Format

Unblocking C7LINK 1

EXECUTED

86

Page 86
Image 86
Dialogic SS7G2X manual Mnble Maintenance Blocking End