Dialogic SS7G2X manual Stpcp Status PCM Print

Models: SS7G2X

1 170
Download 170 pages 7.13 Kb
Page 131
Image 131

Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.14.8STPCP – Status PCM Print

Synopsis

This command requests a status report of the PCMs. The PCM status is one of the following:

OK - Normal operational state

PCM Loss - No signal sensed on the PCM input

Sync Loss - Loss of frame alignment since no frame synchronization has been received

RAI - Remote alarm indication. The remote end indicates that is it is OK, but also indicates that it is detecting an error condition.

AIS - Alarm indication signal. The remote side sends all ones indicating that there is an error condition, or it is not initialized.

BER > 1:10^3 - The PCM is encountering a Bit Error Rate (BER) of 10^3.

BER > 1:10^5 - The PCM is encountering a BER of 10^5.

The Clock Status field is one of the following:

OK - The board is detecting a valid PCM signal which could potentially be used for synchronization.

Standby - The board is detecting a valid PCM signal which will be used for synchronization in the event of failure of the active clock source.

Active - The board is detecting a valid PCM signal which is currently providing synchronization for the Signaling Gateway.

Not OK – The input to the board is not currently suitable for use as a synchronization source.

Fault - A fault has been detected on the board which prevents it being used as a synchronization source.

Syntax

STPCP;

Prerequisites

None

Attributes

CONFIG

Examples

STPCP;

Output Format

PCM Status

 

 

PCM SYNCPRI

PCM Status

Clock

1-3 1

PCM Loss

Fault

1-4 2

SYNC Loss

Not OK

2-3

3

AIS

Not OK

2-4

4

RAI

OK

3-3

1

OK

Active

3-4

1

OK

OK

EXECUTED

131

Page 131
Image 131
Dialogic SS7G2X manual Stpcp Status PCM Print