Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.14.8STPCP – Status PCM Print
Synopsis
This command requests a status report of the PCMs. The PCM status is one of the following:
•OK - Normal operational state
•PCM Loss - No signal sensed on the PCM input
•Sync Loss - Loss of frame alignment since no frame synchronization has been received
•RAI - Remote alarm indication. The remote end indicates that is it is OK, but also indicates that it is detecting an error condition.
•AIS - Alarm indication signal. The remote side sends all ones indicating that there is an error condition, or it is not initialized.
•BER > 1:10^3 - The PCM is encountering a Bit Error Rate (BER) of 10^3.
•BER > 1:10^5 - The PCM is encountering a BER of 10^5.
The Clock Status field is one of the following:
•OK - The board is detecting a valid PCM signal which could potentially be used for synchronization.
•Standby - The board is detecting a valid PCM signal which will be used for synchronization in the event of failure of the active clock source.
•Active - The board is detecting a valid PCM signal which is currently providing synchronization for the Signaling Gateway.
•Not OK – The input to the board is not currently suitable for use as a synchronization source.
•Fault - A fault has been detected on the board which prevents it being used as a synchronization source.
Syntax
STPCP;
Prerequisites
None
Attributes
CONFIG
Examples
STPCP;
Output Format
PCM Status |
|
| |
PCM SYNCPRI | PCM Status | Clock | |
PCM Loss | Fault | ||
SYNC Loss | Not OK | ||
3 | AIS | Not OK | |
4 | RAI | OK | |
1 | OK | Active | |
1 | OK | OK |
EXECUTED
131