Chapter 5 Parameter Definitions

Table 2. Parameter Definitions (Continued)

Name

Description

 

Range

 

Notes

 

 

 

 

 

 

 

One of:

 

 

PCMTYPE

The type of PCM in use

T1

 

 

 

 

E1

 

 

 

 

 

 

PCR

Preventive Cyclic Retransmission

Y or N

Default = N

 

 

 

 

PER

Personality configuration

0 to 255

Default = 0

 

 

 

 

 

 

A period of time in the format:

xx – 00 to 23

 

 

 

xx:yy:zz

yy – 00 to 59

 

 

PERIOD

where:

(yy must be 00,

 

 

when xx is 23)

 

 

• xx = 2 digit hour

 

 

 

zz – 00 to 59

 

 

 

• yy = 2 digit minute

 

 

 

(zz must be 00,

 

 

 

• zz = 2 digit second

 

 

 

when xx is 23)

 

 

 

 

 

 

 

 

PORT

V24 port identifier

1 to 4

 

 

NOTE: Port 1 is not physically accessible.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2905 for M3UA

PPORT

The SCTP port associated with the peer on a

1 to 65535

SNLINKs

SIGTRAN link

3565 for M2PA

 

 

 

 

 

 

 

SNLINKs

 

 

 

 

 

 

 

The type of periodic report:

 

 

 

 

 

• MSC7 – periodic reporting of traffic

 

 

 

 

 

measurements for CCS SS7 links.

One of:

 

 

 

• MSPCM – periodic reporting of traffic

MSC7

 

 

 

measurements for PCMs.

MSSL

 

 

PRTYPE

• MSSL – periodic reporting of traffic

 

 

MSPCM

 

 

 

measurements for SIGTRAN links.

 

 

 

MSEP

 

 

 

• MSEP – periodic reporting of Ethernet

 

 

 

MSSY

 

 

 

port measurements.

 

 

 

• MSSY – periodic reporting of System

 

 

 

 

 

measurements.

 

 

 

 

 

 

 

 

 

 

 

One of:

Default =

 

 

DTRDSR for

 

 

NONE

PTMODE

Mode for serial port

 

ports 1 and 2

DTRDSR

 

 

 

TELNET for

 

 

TELNET

 

 

 

ports 3 and 4

 

 

 

 

 

 

 

 

 

 

RANGE

CIC range

0 to 4095

 

 

 

 

 

 

 

 

RC

The routing context of a SIGTRAN link

0 to 2147483647

 

 

within an Application Server

 

 

 

 

 

 

 

 

 

 

 

 

RDC

Remote Data Centre (RDC) identifier

1 to 4

 

 

 

 

 

 

 

 

RDC1

First choice RDC for a continuous record or

1 to 4

 

 

periodic report

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second choice RDC for a continuous record

 

 

 

 

RDC2

or periodic report.

0 to 4

Default = 0

 

Zero indicates no RDC is assigned.

 

 

 

 

 

 

 

 

 

 

RECORD

The identifier for a continuous data

1 to 6

 

 

collection record

 

 

 

 

 

 

 

 

 

 

 

 

 

REPORT

The identifier for a periodic data collection

1 to 5

 

 

report

 

 

 

 

 

 

 

 

 

 

 

RESET

Performs a reset operation

Y or N

Default = N

 

 

 

 

 

 

34

Page 34
Image 34