Chapter 5 Parameter Definitions
Table 2. Parameter Definitions (Continued)
Name | Description  | 
  | Range  | 
  | Notes  | |
  | 
  | 
  | 
  | 
  | ||
  | 
  | One of:  | 
  | 
  | ||
PCMTYPE | The type of PCM in use  | •  | T1  | 
  | 
  | |
  | 
  | •  | E1  | 
  | 
  | |
  | 
  | 
  | 
  | |||
PCR | Preventive Cyclic Retransmission  | Y or N  | Default = N  | |||
  | 
  | 
  | 
  | |||
PER | Personality configuration  | 0 to 255  | Default = 0  | |||
  | 
  | 
  | 
  | 
  | ||
  | A period of time in the format:  | xx – 00 to 23  | 
  | 
  | ||
  | xx:yy:zz  | yy – 00 to 59  | 
  | 
  | ||
PERIOD | where:  | (yy must be 00,  | 
  | 
  | ||
when xx is 23)  | 
  | 
  | ||||
• xx = 2 digit hour  | 
  | 
  | ||||
  | zz – 00 to 59  | 
  | 
  | |||
  | • yy = 2 digit minute  | 
  | 
  | |||
  | (zz must be 00,  | 
  | 
  | |||
  | • zz = 2 digit second  | 
  | 
  | |||
  | when xx is 23)  | 
  | 
  | |||
  | 
  | 
  | 
  | 
  | 
  | |
PORT | V24 port identifier  | 1 to 4  | 
  | 
  | ||
NOTE: Port 1 is not physically accessible.  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 2905 for M3UA  | ||
PPORT | The SCTP port associated with the peer on a  | 1 to 65535  | SNLINKs  | |||
SIGTRAN link  | 3565 for M2PA  | |||||
  | 
  | 
  | ||||
  | 
  | 
  | 
  | SNLINKs  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | The type of periodic report:  | 
  | 
  | 
  | 
  | |
  | • MSC7 – periodic reporting of traffic  | 
  | 
  | 
  | 
  | |
  | measurements for CCS SS7 links.  | One of:  | 
  | 
  | ||
  | • MSPCM – periodic reporting of traffic  | •  | MSC7 | 
  | 
  | |
  | measurements for PCMs.  | •  | MSSL | 
  | 
  | |
PRTYPE | • MSSL – periodic reporting of traffic  | 
  | 
  | |||
•  | MSPCM | 
  | 
  | |||
  | measurements for SIGTRAN links.  | 
  | 
  | |||
  | •  | MSEP | 
  | 
  | ||
  | • MSEP – periodic reporting of Ethernet  | 
  | 
  | |||
  | •  | MSSY | 
  | 
  | ||
  | port measurements.  | 
  | 
  | |||
  | • MSSY – periodic reporting of System  | 
  | 
  | 
  | 
  | |
  | measurements.  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | ||
  | 
  | One of:  | Default =  | |||
  | 
  | •  | DTRDSR for  | |||
  | 
  | •  | NONE | |||
PTMODE | Mode for serial port  | 
  | ports 1 and 2  | |||
•  | DTRDSR | 
  | ||||
  | 
  | •  | TELNET for  | |||
  | 
  | •  | TELNET | |||
  | 
  | 
  | ports 3 and 4  | |||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | ||
RANGE | CIC range  | 0 to 4095  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
RC  | The routing context of a SIGTRAN link  | 0 to 2147483647  | 
  | 
  | ||
within an Application Server  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | ||
RDC | Remote Data Centre (RDC) identifier  | 1 to 4  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
RDC1 | First choice RDC for a continuous record or  | 1 to 4  | 
  | 
  | ||
periodic report  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | Second choice RDC for a continuous record  | 
  | 
  | 
  | 
  | |
RDC2 | or periodic report.  | 0 to 4  | Default = 0  | |||
  | Zero indicates no RDC is assigned.  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
RECORD | The identifier for a continuous data  | 1 to 6  | 
  | 
  | ||
collection record  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
REPORT | The identifier for a periodic data collection  | 1 to 5  | 
  | 
  | ||
report  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | |||
RESET | Performs a reset operation  | Y or N  | Default = N  | |||
  | 
  | 
  | 
  | 
  | 
  | |
34