Panasonic D6KE manual Monitor Lamp indicators  Filter indicator, Status in Projector Setup menu

Page 29

Monitor Lamp indicators

FILTER indicator

The FILTER indicates the Auto Cleaning Filter (ACF) unit status.

Lamp

Information

 

Check point

 

Remedial measure

indication

 

 

 

 

 

 

 

 

 

Check the REMAINING FILTER

Replace the ACF unit.

Lighting in red

The ACF unit has run out.

 

of STATUS in PROJECTOR

 

 

 

 

 

SETUP menu.

 

 

Blinking in red

The ACF unit is not

Check the ACF unit

Replace the ACF unit.

installed.*1

 

compartment.

 

 

 

 

 

 

 

The ACF unit remains

Check the REMAINING FILTER

Request the dealer to purchase the new

Lighting in

few. The remaining use

 

of STATUS in PROJECTOR

 

ACF unit.

time of the ACF unit is

 

SETUP menu.

 

 

orange

 

 

 

approximately

 

 

 

 

 

 

 

 

 

 

200 hours.*2

 

 

 

 

 

 

Is foreign object blocking the

Remove the foreign object from the ACF

Blinking in

The ACF unit cannot

 

ACF unit operation?

 

unit.

orange

operate properly.

 

 

• When the foreign object still remained,

 

 

 

 

 

contact the dealer.

*1. When the ACF unit is not installed, the filter indicator will blink in red and the power will turn off.

*2. 200 hours is the roughly guided time.

NOTE:

When the FILTER indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up.

When the ACF unit is operating, operational sound may be heard.

In a dusty environment, the guided remaining use time will be shorter. Contact the dealer to purchase the new ACF unit earlier.

If using the projector at high elevations 1 400 - 2 700 m (4 593 - 8 858 ft) sea level and HIGH ALTITUDE MODE in PROJECTOR SETUP menu is OFF, it may cause malfunction of the ACF unit.

Before the FILTER indicator blinks in orange when operational malfunction, mechanical sound of the clutch may be heard.

Maintenance

ENGLISH - 29

Image 29
Contents PT-DZ6700E PT-DW6300E PT-D6000E PT-D5000E To rain or moisture Important Safety NoticeEnvironment care information for users in China Important Safety NoticeFor business users in the European Union Important the Moulded Plug U.K. only For Your SAFETY, Please Read the Following Text CarefullyContents Precautions with regard to safety Precautions with regard to safety Remove the used batteries from the remote control promptly Do not set up the projector outdoorsDo not put your weight on this projector Do not use chemical treated wipes when cleaningDo not reach for the openings beside the optical Replacement of the lamp unit should only be carriedBe sure to always remove the lens during transport Order to get the best picture qualitySecurity OthersAccessories  Top, front and bottom view About Your ProjectorProjector body About Your Projector  Side viewsRemote control Number, and the remote control 2 digits ID number must When multiple projectors are connected as partBe set to match the intended projector. The default IN/OUT terminal. It is effective to use the wired remote Cautions when setting the projectors Setting upProjection method Over 10 cmRemoving and attaching the projection lens Setting up Removing the projection lens from the projector  Attaching the projection lens to the projectorMains lead  Connecting Adjusting focus, zoom and shift  Switching on the projectorPower switch AC in terminal Projecting Adjustment range after lens Position optical shift Projecting  Switching off the projector Direct power off function Setting up the image position automatically Remote control operationOperating range  Facing to the projectorStopping the projection Switching the input signalClearing the on-screen menu Changing the picture aspect ratioDisplaying the status of the projector Using an assigned functionResetting to the factory default Main menu and Sub-menu Menu NavigationPT-DZ6710E/PT-DZ6700E/PT-DW6300E only RS-232CSecurity Menu Navigation Operating procedure  Adjusting with the bar scale itemsNavigating through the menu  Displaying the Main menuManaging the indicated problems Monitor Lamp indicators LAMP1/LAMP2 indicator  Temp indicatorStatus in Projector Monitor Lamp indicators  Filter indicatorStatus in Projector Setup menu  When to replace the lamp unit ReplacementReplacing the Lamp unit  Before replacing the Lamp unitLamp unit cover fixing screw  Removing and replacing the lamp unitLamp u nit fixing screws HandleReplacing the Auto Cleaning Filter ACF Troubleshooting Technical Information List of compatible signalsPT-DZ6710E  Display dots of each modelPT-DZ6700E PT-DW6300ETechnical Information SpecificationsSerial Ceiling mount Ceiling mount bracket safeguards Attachment procedure Unit mm inch DimensionsTrademark acknowledgements Index Index