Panasonic PT-DW6300K, D6KE Replacement, Replacing the Lamp unit,  Before replacing the Lamp unit

Page 30

Replacement

Replacing the Lamp unit

Before replacing the Lamp unit

Turn off the POWER switch of the projector in proper way and disconnect the mains plug from the mains socket.

Wait for more than 1 hour and make sure the lamp unit and the surroundings are cooled enough.

Prepare a Phillips-head screwdriver.

Contact the dealer to purchase a replacement lamp unit (ET-LAD60:1 bulb unit, ET-LAD60W: 2 bulb units).

When the projector is mounted on the ceiling, do not work directly under the projector or put your face closer to the projector.

CAUTION:

• The lamp may explode by shocks or chipping damage.

NOTE:

Prior to replacing the lamp unit, allow it to cool down to prevent the risk of burns, damage and other hazards.

Do not attempt replacement with an unauthorised lamp unit.

Both lamps must be set in a lamp unit. If only one lamp is set, the power will not work.

When to replace the lamp unit

The lamp unit is consumable and the brightness decreases by duration of usage. The LAMP1/LAMP2

indicators will inform you of the replacement timing at 1 800*2 hours, and at 2 000*1 hours, the projector will be turned off. Those figures are rough guidance and might be shortened by the usage conditions, characteristics of the lamp unit, environmental conditions, and so on. You can check the duration of usage time using LAMP1/ LAMP2 of STATUS in the PROJECTOR SETUP menu.

On screen

LAMP indicator

Indication

REPLACE LAMP

LAMP

Maintenance

Over 1 800*2 hours

REPLACE LAMP” is displayed on the upper left

 

of the screen for 30 seconds. Press any button to

 

 

clear the screen, or disappears after 30 seconds.

Lights in red

Over 2 000*1 hours

REPLACE LAMP” is displayed on the upper left

of the screen, and it will stay until you respond.

 

 

To clear the screen, press any button.

 

CAUTION:

If you keep using the lamp unit after 2 000*1 hours, it cause the damage of the projector. Automatically the projector will be powered off after 10 minutes.

NOTE:

The guide times, 1 800*2 and 2 000*1 hours, are rough estimates based on certain conditions and are not a guaranteed time.

For more information about the lamp unit, see the instructions which is provided with the lamp unit.

*1. 3 000 hours for PT-D5000E.

*2. 2 800 hours for PT-D5000E.

ENGLISH - 30

Image 30
Contents PT-DZ6700E PT-DW6300E PT-D6000E PT-D5000E Important Safety Notice To rain or moistureImportant Safety Notice For business users in the European UnionEnvironment care information for users in China For Your SAFETY, Please Read the Following Text Carefully Important the Moulded Plug U.K. onlyContents Precautions with regard to safety Precautions with regard to safety Do not put your weight on this projector Do not set up the projector outdoorsRemove the used batteries from the remote control promptly Do not use chemical treated wipes when cleaningBe sure to always remove the lens during transport Replacement of the lamp unit should only be carriedDo not reach for the openings beside the optical Order to get the best picture qualityOthers SecurityAccessories About Your Projector Projector body Top, front and bottom view  Side views About Your ProjectorRemote control Be set to match the intended projector. The default When multiple projectors are connected as partNumber, and the remote control 2 digits ID number must IN/OUT terminal. It is effective to use the wired remoteProjection method Setting up Cautions when setting the projectors Over 10 cm Removing the projection lens from the projector Setting upRemoving and attaching the projection lens  Attaching the projection lens to the projector Connecting Mains leadPower switch AC in terminal  Switching on the projector Adjusting focus, zoom and shift ProjectingProjecting  Switching off the projector  Direct power off function Adjustment range after lens Position optical shift Operating range Remote control operationSetting up the image position automatically  Facing to the projectorClearing the on-screen menu Switching the input signalStopping the projection Changing the picture aspect ratioUsing an assigned function Resetting to the factory defaultDisplaying the status of the projector Menu Navigation Main menu and Sub-menuRS-232C PT-DZ6710E/PT-DZ6700E/PT-DW6300E onlyMenu Navigation SecurityNavigating through the menu  Adjusting with the bar scale items Operating procedure  Displaying the Main menu LAMP1/LAMP2 indicator Monitor Lamp indicatorsManaging the indicated problems  Temp indicatorMonitor Lamp indicators  Filter indicator Status in Projector Setup menuStatus in Projector Replacing the Lamp unit Replacement When to replace the lamp unit  Before replacing the Lamp unitLamp u nit fixing screws  Removing and replacing the lamp unitLamp unit cover fixing screw HandleReplacing the Auto Cleaning Filter ACF Troubleshooting List of compatible signals Technical InformationPT-DZ6700E  Display dots of each modelPT-DZ6710E PT-DW6300ESpecifications Technical InformationSerial Ceiling mount bracket safeguards  Attachment procedureCeiling mount Dimensions Trademark acknowledgementsUnit mm inch Index Index