Replacement
Replacement procedure
Removing and replacing the lamp unit
1.Use a
Slide the lamp unit cover to the control buttons and pull to remove.
4.Hold the handle of the new lamp unit and replace it in correct direction.
5.Press in the lamp unit until it clicks and make sure the unit is installed securely.
6.Tighten the “lamp unit fixing screws” (3 screws) securely with a
Lamp unit cover fixing screw
Lamp unit cover
2.Use a
3.Hold the handles of the lamp unit and pull the used lamp unit gently from the projector.
Lamp unit fixing screws | Handle |
Fan electric power connector
7.Attach the lamp unit cover and tighten the “lamp unit cover fixing screw” (1 screw) securely with a
Slide the lamp unit cover to the hinge side along the guide and push in to attach securely.
Make sure the fan electric power connector of the lamp unit cover is inserted securely to the projector’s connector.
Handle | Lamp unit fixing screws |
NOTE:
•The lamp unit and the lamp unit cover must be attached correctly and securely. Failure to do so, the projector will bot be turned on for the protection circuit.
•When the lamp unit is replaced, the duration of usage time will be reset to "0".