Chapter 2
Install and Initialize the Uninterruptable Power Supply
This chapter describes how to install and initialize the Uninterruptable Power Supply (UPS) on the Business Communications Manager (BCM) 200, 400, and 1000 models.
This chapter describes the following:
•Install and Initialize the UPS on page 23
•UPSConsoleToggle Service on page 24
Install and Initialize the UPS
Use this procedure to install and power up the Business Communications Manager through the UPS. Refer also to the UPS product installation manual for detailed instructions.
1Plug the UPS power cord into the AC power source (wall outlet).
2Plug the BCM power cord into the UPS.
3Connect the serial cable from the Business Communications Manager to the UPS.
4Ensure you have a LAN connection from the Business Communications Manager to the Unified Manager workstation.
5
6
7Wait for the Business Communications Manager to finish
8This procedure is complete.
Initialize the serial port
The Unified Manager provides a means to modify the serial port configuration and UPS service settings. When you enable the UPS device using the Unified Manager interface, Unified Manager turns the console service OFF and turns the UPS service ON. Conversely, if the UPS serial cable is disconnected, the BCM Unified Manager turns the console service ON and turns the UPS service OFF.
Use this procedure to initialize the UPS serial port:
1Connect the serial cable from the BCM to the UPS.
2Access the correct Business Communications Manager in your network from the Unified Manager workstation browser.
3Select the Services key from the Unified Manager main page and expand the navigation tree. A list of available services appears in the Services information frame.
4Select the UPS heading from the navigation tree window.
UPS Installation and Configuration Guide