Nortel Networks P0607274 0 manual Chapter Uninterruptable Power Supply UPS Overview

Page 15

15

Chapter 1

Uninterruptable Power Supply (UPS) Overview

This book describes how to install, configure and monitor the Uninterruptable Power Supply (UPS) on the Business Communications Manager (BCM) 200, 400, and 1000 models.

This chapter provides an overview of the UPS functionality and describes the following information:

BCM and UPS power and control connections on page 16

UPS threshold values on page 17

Alarm and event reporting on page 17

Operational measurements and accounting on page 20

UPS default configuration settings on page 20

UPS Overview

A UPS device maintains continuous operation during power interruption or failure conditions and is an optional component of the BCM. The UPS device provides power source monitoring and battery backup activation so that critical BCM functionality is maintained.

In a power failure situation, the UPS provides sufficient time to either correct the problem or activate a contingency plan to sustain services. The UPS is configured to perform a graceful shutdown of the BCM two minutes before the UPS battery power is drained. The UPS can perform a graceful shutdown of the BCM 200, 400, and 1000 models.

The ability to turn the power off after a graceful system shutdown is only provided on BCM 200 and 400 models. In the event that the UPS battery power is drained on a BCM 1000, the UPS performs a halt after a graceful system shutdown

Business Communications Manager release 3.5 and higher supports the American Power Conversion (APC) UPS device. The UPS control software enables the configuration of various operational settings.

The interaction between the UPS and the Business Communications Manager occurs in three stages:

1Configuration—this stage sends configuration information to the UPS device and requires minimal user interaction.

2Monitoring—this stage is a steady-state, periodic monitoring cycle where the BCM reads the status of the UPS. This stage requires minimal user interaction.

3Failure condition—this stage initiates an action when a threshold value is surpassed. The BCM requires major user interaction in the case of a planned system shutdown.

UPS Installation and Configuration Guide

Image 15
Contents Part No. P0607274 March 24 North American Regulatory Information SafetyRadio-frequency Interference Telecommunication RegistrationElectromagnetic Compatibility Canadian Regulations please read carefully Telephone Company RegistrationRights of the Telecommunications Company RepairsFederal Communications Commission FCC Notice US Regulations please read carefullyImportant Safety Instructions Use Risk of shock Preface P0607274 Display Tips PrefaceAcrobat Reader display setup selections Symbols used in this guideHow to Get Help Text conventionsRelated publications Preface P0607274 UPS Overview Chapter Uninterruptable Power Supply UPS OverviewBCM Input Power Source BCM and UPS power and control connectionsUPS threshold values Alarm and event reportingUPS Event messages Uninterruptable Power Supply UPS Overview UPS Event messages Operational measurements and accounting UPS default configuration settingsShutdown Uninterruptable Power Supply UPS Overview P0607274 Initialize the serial port Install and Initialize the UPSUPS Configuration screen UPSConsoleToggle ServiceEnable UPSConsoleToggle Enable the console batch file Monitor the UPS Chapter Monitor the Uninterruptable Power SupplyUPS Status Monitor screen Access the UPS Status monitorUPS OMs report Access the UPS OM and log reportsUPS Log file report Access the UPS status reportUPS status report Test the UPSMonitor the Uninterruptable Power Supply