Read Me First!

Your new Maple Systems OIT comes from the factory configured with the default communication settings: 9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, no turn-around delay, 90￿ viewing angle, interactive mode, CR line terminator, underline cursor, 1 space tab width, local echo enabled, local setup enabled, local keyboard enabled, key click enabled, block echo enabled. You can change these settings through the MAP450D’s local setup menus or by using the STEPware-100 configuration software (sold separately). If you want to store messages in the MAP450D, you must use STEPware-100.

To ensure that the OIT meets CE compliance, it is necessary to follow all installation procedures described in this manual.

Introduction

Thank you for purchasing a Maple Systems MAP450D. You have selected a rugged, reliable, and powerful operator interface for your application. This booklet describes the steps necessary to ensure trouble-free OIT system operation. Please

read this booklet carefully!!

Static Awareness

 

It is best NOT to remove the rear cover on the OIT except when accessing the

 

terminal block pins or panel mounting the OIT. When the rear cover is removed,

 

the circuitry inside is exposed to possible damage by electrostatic discharge during

 

handling. Minimize the possibility of electrostatic discharge by:

CAUTION

• Discharging personal static by grounding yourself prior to handling the OIT.

 

• Handling the OIT at static-free, grounded work stations.

 

• Connecting the chassis of the OIT to a clean ground.

 

• Placing the OIT into an anti-static bag during transport.

Unpacking the Unit

Carefully unpack the OIT. Please read any instructions or cautions that appear on the shipping container. Check all material in the container against the enclosed packing list. Maple Systems, Inc., will not accept responsibility for shortages against the packing list unless notified within 30 days. The equipment and its accessories were inspected and tested by Maple Systems before shipment; all of the equipment should be in good working order. Examine the equipment carefully; if any shipping damage is evident, notify the carrier immediately. You are responsible for claim negotiations with the carrier. Save the shipping container and packing material in case the equipment needs to be stored, returned to Maple Systems, or transported for any reason.

1010-0046A, REV 00

Image 3
Contents Installation Manual Applications Assistance Unpacking the Unit Read Me FirstIntroduction Static AwarenessTable of Contents Power Supply Selection Control Panel Design GuidelinesControl Panel Grounding Other Steps to Improve Noise Immunity OIT Cable RoutingHost/Controller Connecting the MAP450D to a Host ControllerFerrite coil RS-422/485 Interactive & Block modes RS-232 Interactive & Block modesOIT RS-422/485 Network modeOIT #2 Network Termination Cable shield must not be used as the signal ground Set Jumper for 3-Wire RS-422/485Panel Mount Mounting the MAP450DMAP450D Pedestal Mounting Pedestal/Pendent MountMounting Plate Benchtop MountConnecting the MAP450D to a PC Configuring the MAP450DMechanical Appendix a OIT Hardware SpecificationsFront View Rear View Appendix a con’t Dimensional OutlineAppendix B Differences Between MAP450D and MAP450B