MGE UPS Systems 100 Technical data sheet, RS485 Port, Modem, Contact inputs, Power supply

Page 12

1. Presentation

1.4 Technical data sheet

Functions

Parameters

Characteristics/Default values

Possible values

 

 

 

 

RS232 Port

Rate

9600

9600

 

Data bits

8

8

 

Stop bits

1

1

 

Parity

None

Even, odd

RS485 Port

Rate, bits, stop

1200, 8, 1

See technical support

 

Parity

None

documentation

 

Mode

2 wires

2 wires / 4 wires

 

Master / slave

Master

Master

 

Bias

With

With / without

 

Impedance matching

Without

With / without

 

Cable cross-section

0.08 - 0.6 mm2 (28/20 AWG)

 

Modem

Analogue

V.34/33.6 kbps

 

 

 

Error correction: V.42 LAPM and MNP 2-4

 

 

 

Data compression: V.42b and MNP5

 

 

Country

Works with 39 country profiles

 

 

 

European CTR21 compatibility

 

 

Protection

Line protection included

 

 

 

 

 

Contact inputs

Dry contacts

Normally open (NO)

NO / NC

 

 

0.08 - 0.6 mm2 (28/20 AWG)

 

 

Number

2 (card version)

0 to 2

 

 

2+4 (external version) 0.08 - 0.5 mm2 (28/20 AWG)

0 to 6

 

Distance

10m maximum

 

 

 

 

 

Power supply

Voltage

5V DC

 

(external version)

Current

1A

 

 

 

 

 

Comment: only MGE UPS SYSTEMS can be connected to the RS485 link.

Page 12 - 34003602EN/AB

Image 12
Contents PowerServicesTM TelPac Installation manual2 34003602EN/AB Special precautions IntroductionEnvironment Recycling of packagingForeword EMC compatibilityFederal Communication Commission FCC statement Radio and Telecommunications compatibilityModem compatibility and supported countries List of countries supported by the modemPictogram symbols Contents Maintenance Unpacking and checking the contents PresentationOverview Country Teleservice Centre FunctionsTechnical data sheet Power supplyRS485 Port ModemIndicator lights Status Green UPS indicator Card version External versionStatus Red CD indicator Card version External version Installation ProcedurePreliminary check Various installation types Recommendations Fitting the warning labelMGE Attention Onduleur sous Teleservice Galaxy PWSetting up the RS485 link Single-unit type installationGeneral UPS with JbusImpedance matching and bias settings Configuring the shielding terminal = ShieldingConfiguring the RS485 card for Comet For CometConfiguring the Rauz card for Galaxy Installing the PowerServices TelPac card ConnectionComet S31 7.5/10KVA ConnectionsComet S31 15/20KVA Open the doors giving access to Galaxy view with doors open and protective panels in place Connecting contact type inputs PowerServices TelPac card 2 inputsPowerServices TelPac external unit 2 inputs + 4 extensions 5V BMaintenance Cable diagramsComet link cable ref