Introduction

The APC Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment from utility power blackouts, brownouts, sags and surges. The UPS filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power. The UPS provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged.

INSTALLATION

Read the Safety Instruction sheet before installing the UPS.

Unpacking

Inspect the UPS upon receipt. Notify the carrier

ƒ Literature kit containing:

and dealer if there is damage.

ƒ

Software CD

The packaging is recyclable; save it for reuse or

ƒ Smart-UPS User Manuals CD

dispose of it properly.

ƒ

Serial cable

Check the package contents.

ƒ Six output power cords

ƒ

UPS

ƒ Two battery cable assemblies

ƒ

Front bezel

ƒ

Two ground wires

 

 

 

 

ƒ

Product documentation, warranty

 

 

 

information, and safety information

 

 

ƒ

Network Management Card

 

 

 

documentation

Specifications

TEMPERATURE

32° to 104° F (0° to 40° C)

This unit is intended for

OPERATING

indoor use only. Select a

STORAGE

5° to 113° F (-15 to 45 ° C) charge UPS battery every six months

location sturdy enough to

 

 

handle the weight.

MAXIMUM

 

 

Do not operate the UPS where

ELEVATION

 

OPERATING

10,000 ft (3,000 m)

there is excessive dust or the

STORAGE

50,000 ft (15,000 m)

temperature and humidity are

 

 

outside the specified limits.

HUMIDITY

0% to 95% relative humidity, non-condensing

Ensure the air vents on the

 

 

 

 

front and rear of the UPS

 

 

are not blocked.

 

 

 

WEIGHT

244 lbs (111 kg)

 

UPS

 

UPS WITH

284 lbs (129 kg)

 

PACKAGING

 

 

1

Image 3
Contents APC Smart-UPSRT UXI/UXICH Page Introduction 220/230/240 V Models Page Ethernet Port Battery Safety Connect the Ground and Wire the Battery System Connect Equipment and Power to the UPS Page Operation Bypass mode. Refer to Troubleshooting in this manual User Configurable Items Function Factory User Selectable Description Default Choices Connect the EPO Emergency Power OFF Battery Replacement Service Troubleshooting Bypass LED Illuminates Regulatory Agency Approvals and Radio Frequency Warnings Declaration of Conformity APC Worldwide Customer Support