American Power Conversion 240 VAC, 8000 VA, 220 VAC, 10000 VA user manual Ethernet Port

Page 6

CIRCUIT BREAKERS

8000/10000 VA

 

The input circuit breaker must be switched on for the UPS to operate.

 

 

 

 

 

 

 

The input circuit breaker protects the UPS from extreme overload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

conditions.

 

Input Circuit

 

 

 

 

 

Breaker

 

 

 

 

 

 

 

 

 

 

 

 

8000/10000 VA

 

IEC 320-C13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Circuit

 

10 A total current

IEC 320-C19

 

from four

Breakers

 

16 A for each

 

receptacles

 

 

 

 

 

 

 

receptacle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BASIC CONNECTORS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power management software and interface kits can be used with the UPS.

Serial Com

 

Use only interface kits supplied or approved by APC.

 

 

Any other serial interface cable will be incompatible with the UPS

 

 

 

 

 

 

 

connector.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect the UPS to the network using the Network Management Card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emergency Power Off terminal allows the user to connect the UPS to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

central EPO system.

 

EPO Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The UPS features a transient voltage surge-suppression (TVSS) screw for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connecting the ground lead on surge suppression devices such as telephone

TVSS Screw

 

 

and network line protectors.

 

 

 

 

 

 

 

 

When connecting grounding cable, disconnect the unit from the utility

 

 

 

 

 

 

 

power outlet.

 

 

 

 

 

 

 

 

External battery packs must be connected to these connectors located on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the rear panel of the unit.

 

External Battery

 

 

 

 

 

 

Pack Connectors

 

 

 

 

4

Image 6
Contents APC Smart-UPSRT UXI/UXICH Page Introduction 220/230/240 V Models Page Ethernet Port Battery Safety Connect the Ground and Wire the Battery System Connect Equipment and Power to the UPS Page Operation Bypass mode. Refer to Troubleshooting in this manual User Configurable Items Function Factory User Selectable Description Default Choices Connect the EPO Emergency Power OFF Battery Replacement Service Troubleshooting Bypass LED Illuminates Regulatory Agency Approvals and Radio Frequency Warnings Declaration of Conformity APC Worldwide Customer Support