Specifications

8.0 Specifications

For a complete list of specifications, see the APC BC300 Series Installation Guide.

Table 7: General Specifications

Utility tolerance

+10%, 15% (programmable)

 

 

Bypass tolerance

±10% (programmable)

 

 

Input frequency ±6% (programmable)

60 Hz

 

 

Output frequency

 

- utility synchronized:

60 Hz ±6%

- free running:

60 Hz ±0.1%

 

 

Current distortion

0-5%

 

 

Tolerance

 

- symmetrical load:

±1%, static.

- asymmetrical load:

±3%, static. (100% imbalance, provided

 

output current rating is not exceeded.)

- load step 0-100:

±5%.

 

 

Distortion (linear load)

0-3%

 

 

Overload capacity

 

- normal operation, 1 minute

250%

- normal operation, 10 minutes

150%

- battery operation, 1 minute

150%

- battery operation, 10 minutes

125%

 

 

Audible noise (dBa)

dBa

 

 

Maximum Humidity (non condensing)

95%

 

 

Efficiency

95%

 

 

For Users in the United States Only

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Installation Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense.

990-1403

User Guide APC BC300 Series 40kW 208/450/480V UPS

29

Image 29
Contents Copyright 2002 APC Denmark ApS APC BC300 Series 40kW 208/450/480V User GuideThank You Safety Symbols used in this manualUser Guide APC BC300 Series 40kW 208/450/480V UPS Contents Display Unit IntroductionIntroduction UPS Stop/Start UPS Stop/StartUPS Stop for stand-by UPS Start from stand-byOperation OperationOperating Modes Sample Display Operation Mode DescriptionOperation Modes Using the keys Key Function Using the KeysDisplaying Measurements Operation Parameter Settings Parameter SettingsAPC Technical Support before changing this Parameter SettingsAlarms and Events Alarms and EventsSilencing the Audible Alarm Displaying the Alarm LogAlarm Description Action Message Alarm MessagesPossible Alarms Alarms and Events Alarms and Events Alarms and Events Alarms and Events 990-1403 Alarms and Events Alarms and Events Alarms and Events Displaying the Events Log Log Messages Mode DescriptionMaintenance and Testing Maintenance and TestingPreventive Maintenance Check Battery Monitor TestBattery Capacity Test Maintenance and Testing Start-up and Shutdown Procedure Start-up and Shutdown ProcedureStart-up from Maintenance Bypass Shutdown ProcedureIf you have shut the loads down Move on to step Specifications SpecificationsGeneral Specifications For Users in the United States OnlyFor Users in Canada Optional Service Programs Optional Hardware and Software FeaturesOptions OptionsOn-Site Service Preventive Maintenance VisitRemote Monitoring Service External Battery Installation ServiceLife Support Policy APC BC300 Series UPS Limited Factory WarrantyWarranty How to Contact APC How to Contact APCAPC Corporate Fairgrounds Road West Kingston, RIHow to Contact APC