APC BC300 manual Options, Optional Hardware and Software Features, Optional Service Programs

Page 31

Options

9.0 Options

APC offers many options for the APC BC300 Series UPSs. For more information, contact your local APC office. Note that some options only apply to certain models.

9.1Optional Hardware and Software Features

9.1.1 Battery Temperature

Compensation:

Enables the UPS to adapt the charging voltage to the battery temperature. This is for units with external batteries and this option monitors the temperature in one battery cabinet.

9.1.2 Communication

Interface Board:

If you would like to use shutdown software or remote monitoring, your UPS must have this internal circuit board. The board offers three methods of communicating with the UPS:

1.Normally open or normally closed contacts that indicate UPS ON, bypass operation, battery operation, and low battery. (You can choose this method for an AS/400 monitoring system.)

2.RS232 Serial Communications port.

3.Zero to 20 mA current loop.

Fan Monitor:

If the unit’s fans are not functioning properly, this option will activate a “Fan fault” alarm.

9.1.3 Maintenance

Bypass Panel:

An external bypass switch lets you conveniently transfer your protected load equipment to direct AC input power when it is time to service the UPS. The cabinet includes an AC disconnect.

Parallel Board:

This option allows your qualified installer to connect two or more units in parallel. The parallel board ensures proper control of parallel units and proper load sharing between the units. Each unit to be connected in parallel requires one of these boards. Each board includes 23 feet (7 meters) of interconnection cable. An APC Application Engineer should be involved in all parallel unit installations. Call APC Global Service or the nearest APC office for details.

9.2Optional Service Programs

Contact APC or visit www.apc.com for further information on a large range of end-to-end service and support which supplements the APC BC300 Series UPS Limited Factory Warranty.

9.2.1 Start-Up Service

This service verifies that the APC system has been properly installed and includes comprehensive tests, correct start-up and basic customer training on usage. Performed during normal business hours. Does not include electrical installation or wiring work.

990-1403

User Guide APC BC300 Series 40kW 208/450/480V UPS

31

Image 31
Contents Copyright 2002 APC Denmark ApS APC BC300 Series 40kW 208/450/480V User GuideUser Guide APC BC300 Series 40kW 208/450/480V UPS Safety Symbols used in this manualThank You Contents Introduction IntroductionDisplay Unit UPS Start from stand-by UPS Stop/StartUPS Stop/Start UPS Stop for stand-byOperation OperationOperation Modes Sample Display Operation Mode DescriptionOperating Modes Using the keys Key Function Using the KeysDisplaying Measurements Operation Parameter Settings Parameter SettingsAPC Technical Support before changing this Parameter SettingsDisplaying the Alarm Log Alarms and EventsAlarms and Events Silencing the Audible AlarmPossible Alarms Alarm MessagesAlarm Description Action Message Alarms and Events Alarms and Events Alarms and Events Alarms and Events 990-1403 Alarms and Events Alarms and Events Alarms and Events Displaying the Events Log Log Messages Mode DescriptionBattery Monitor Test Maintenance and TestingMaintenance and Testing Preventive Maintenance CheckBattery Capacity Test Maintenance and Testing Shutdown Procedure Start-up and Shutdown ProcedureStart-up and Shutdown Procedure Start-up from Maintenance BypassIf you have shut the loads down Move on to step For Users in the United States Only SpecificationsSpecifications General SpecificationsFor Users in Canada Options Optional Hardware and Software FeaturesOptional Service Programs OptionsExternal Battery Installation Service Preventive Maintenance VisitOn-Site Service Remote Monitoring ServiceLife Support Policy APC BC300 Series UPS Limited Factory WarrantyWarranty Fairgrounds Road West Kingston, RI How to Contact APCHow to Contact APC APC CorporateHow to Contact APC